Bernecker&Rainer Industrie-Elektronik Ges.m.b.H 5E903029 Manuel D’Utilisation

Page de 29
 Error codes
Data sheet V 1.00 5E9030.29
23
7 Error codes
7.1 Error messages and error numbers
Operating errors
Value
Name
Description
0
ERR_NONE
No errors (OK)
1
ERR_OTHER
Miscellaneous operating error, unrecognized command
2
ERR_PARAMETER
Incorrect number of parameters
3
ERR_AUTH
Authentication error (A or B)
4
ERR_SECTOR
Invalid range for sector (0-63)
5
ERR_BLOCK_SRC
Invalid range for source block (0-255)
6
ERR_WRITE
No data found for writing
7
ERR_KEY_EE
No key found for writing
8
ERR_KEY_STORE
Could not save key
9
ERR_BLOCK_DST
Invalid range for destination block (0-255)
10
ERR_NO_TAG
No tag in range
11
ERR_BLOCK_NUM
Incorrect values for source/destination blocks
12
ERR_TAG_NUM
Invalid tag number
13
ERR_KEY
Invalid key
14
ERR_REMOTE
X-modem firmware update canceled (not used)
15
ERR_SYNC
X-modem firmware update packet start not found (not used)
16
ERR_RETRY
X-modem firmware update number of retry attempts (not used)
17
ERR_READ
Could not read data
18
ERR_INCDECRES
Error accessing value block
19
ERR_LOCK
Could not lock block
20
ERR_AFI
Error writing AFI value
21
ERR_DSFID
Error writing DSFID value
22
ERR_SYSINFO
Could not read system information
23
ERR_INVENTORY
Could not execute inventory command due to incorrect parameter (value) or internal RFID stack
error
24
ERR_STAY_QUIET
Could not set specified ISO tag to STAY_QUIET (no longer accessible)
25
ERR_RESET2READY
Could not set specified ISO tag to READY (after a preceding STAY_QUIET)
Table 16: Operating errors