Hangzhou Hikvision Digital Technology Co. Ltd. K1T606MF Manuel D’Utilisation

Page de 153
Face Recognition Terminal User Manual 
114 
 
Event Linkage 
For the event linkage, the alarm event can be divided into four types: device event, alarm input, 
door event, and card reader event.   
Steps: 
1.  Click  to  select  the  linkage  type  as  Event  Linkage,  select  the  access  control  device  as  event 
source, and select the event type from the dropdown list. 
  For Device Event, select the detailed event type from the dropdown list. 
  For  Alarm  Input,  select  the  type  as  alarm  or  alarm  recovery  and  select  the  alarm  input 
name from the table. 
  For Door Event, select the detailed event type and select the door from the table. 
  For Card Reader Event, select the detailed event type and select the card reader from the 
table. 
2.  Set the linkage target,  select the access  control  device from the dropdown list as the linkage 
target, and switch the property from 
  to 
  to enable this function. 
  Alarm Output: The alarm output will be triggered for notification. 
  Access Control Point: The door status of open, close, remain open, and remain close will 
be triggered. 
Note:
 The door status of open, close, remain open, and remain close cannot be triggered 
at the same time.   
3.  Click Save button to save parameters.     
Card Linkage 
Steps: 
1.  Click to select the linkage type as Card Linkage
2.  Select the card from the dropdown list and select the access control device as event source.   
3.  Select the card reader from the table for triggering.   
4.  Set the linkage target, select the access  control  device from the dropdown list as the linkage 
target, and switch the property from 
    to 
  to enable this function. 
Alarm Output: The alarm output will be triggered for notification. 
5.  Click Save button to save parameters.   
8.11 
Door Status Management   
Purpose: 
The door status of the added access control device will be displayed in real time. You can check the 
door status and the linked event(s) of the selected door. You can control the status of the door and 
set the status duration of the doors as well. 
8.11.1 
Access Control Group Management 
Purpose: