SALUS North America Inc. SS901ZB Manuel D’Utilisation

Page de 2
Version 1 
Installation/Quick Start Guide: Water Leak Sensor (SS901ZB) 
Visit www.salusinc.com for the User Manual
 
In the Box 
 
 
 
 
 
 
Tools Needed 
  Note: 
 
 
 
 
 
 
 
 
 
  Additional  equipment  may  be  required  due  to 
building  construction  or  materials,  or  other  radio 
interference that may reduce the radio range. 
Water Leak Sensor w/ Battery 
(1x CR2, 3V Lithium) 
Stand 
Sensor Cable 
Installation/ 
Quick-start Guide 
Screws and Anchors 
Adhesive Pad 
 
#1 Phillips Screwdriver 
 
 
 
 
 
 
 
 
 
 
 
P
AIRING 
I
NSTRUCTIONS
 
• 
Follow your system’s instructions to prepare to add devices to the 
system. 
• 
Remove the Face Plate from the sensor by turning the Face Plate 
counter-clockwise and pull the battery tab to start the pairing 
process. 
• 
When the sensor is detected and added to the system, replace the 
Face Plate by aligning the dots and turning the Face Plate clockwise.  
• 
Make sure the dots are fully aligned for a proper seal, then proceed 
to the sensor installation. 
 
I
NSTALLATION 
I
NSTRUCTIONS
 
• 
Identify a level surface for the sensor, where water will likely 
accumulate in the event of a leak. If the sensor is too wide for 
placement at the desired location, the stand can be used for a 
narrower profile. 
For tighter 
locations or 
locations with 
radio problems, 
use the 
included 
Sensor Cable. 
I
NSTALLING THE 
S
ENSOR 
C
ABLE 
(O
PTIONAL
• 
To install the Sensor Cable, first run the cable to the desired location, 
and fasten the winged end of the Sensor Cable into place.  Note that 
the tips are angled to improve the sensing ability when the tips are 
near a surface. 
 
 
 
 
 
 
 
• 
Insert the square end of the Sensor Cable into the terminals on the 
stand. 
• 
Screw down both terminals until the cable is firmly held in place 
• 
Mount the Stand to the wall or other surface using the supplied 
double-sided adhesive pad or screws. 
• 
Insert the Water Leak Sensor into the stand to begin operation.  
 
T
ESTING THE 
S
ENSOR
 
• 
To test the sensor, remove it from the stand or floor 
• 
Insert the sensor into the stand 90 degrees from upright in either 
direction to short the contacts on the sensor. 
• 
The sensor will send a message to the connected home system 
indicating a water leak. The LED will not light up to preserve battery 
life. 
 
 
 
 
 
 
R
EPLACING THE 
B
ATTERY
 
(Use only Panasonic CR2 3V lithium battery) 
• 
Grasp the top of the sensor Face Plate, rotate counter-clockwise 
and lift from the sensor Body.  
• 
Grasp the battery from both ends and lift to remove the battery 
from the sensor. 
• 
Insert a new battery into the sensor, observing the proper polarity.  
• 
Position the sensor Face Plate over the Sensor Body, aligning the 
dots on the Face Plate and Body, then rotate clockwise to align the 
dots again to close. 
 
Surface Install 