Valeport Ltd 0804IDU Manuel D’Utilisation

Page de 83
 
HydrINS 2 / HydrINS 2 Mini flow meter  
Installation Manual  
Page 17 / 83 
3.2  Models in the HydrINS 2 / HydrINS 2 Mini flow meter range 
The following table is a selection guide to identify the most appropriate HydrINS 2 model according 
to the pipe diameter and dimensions as shown in the diagram above:  
 
A: Total stem length (see the above diagram) 
 
B: Stacking length of HydrINS 2/HydrINS 2 Mini accessories (see dimensions on the diagram 
above)  
 
C: Stacking height at insertion level (theoretical value, must be checked on site) 
HYDREKA 
Catalogue 
Number 
Model 
Hydrins 
Dimension 
mm 
(inches) 
Dimension 
mm 
(inches)  
Dimension 
C* 
mm 
(inches) 
Available 
insertion 
length 
= A-(B+C) 
mm 
(inches) 
Usable on pipe 
diameters 
mm 
(inches) 
 
 
 
 
 
 
Profile  Centre 
SI_HYDA2P-30 
300  
689  
(27.12) 
234     
(9.21) 
200     
(7.87) 
255        
(10) 
< 250 
(9.84)  
< 500 
(19.68) 
SI_HYDA2P-50 
500  
869  
(34.21) 
234     
(9.21) 
200      
(7.87) 
400   
(15.75) 
< 400 
(15.75) 
< 800 
(31.5) 
SI_HYDA2P-70 
700  
1109 
(43.66) 
234     
(9.21) 
200      
(7.87) 
675  
(26.57) 
< 650 
(25.59) 
< 1300 
(51.18) 
SI_HYDA2P-
100 
1000  
1409 
(55.47) 
234     
(9.21) 
200      
(7.87) 
975  
(38.38) 
< 950 
(37.4) 
< 1900 
(74.8) 
SI_HYDE2-15 
Mini  
500 (19.68) 
165       
(6.5) 
200      
(7.87) 
175      
(6.89) 
< 180  
(7.08) 
< 300 
(11.81) 
Table 7: Flow meter selection table according to the flow range to be measured 
Note: This is a theoretical value. It is provided as an indication, but must be checked on site. 
The model is also chosen according to the space available in the port. Allow sufficient distance above 
the insertion point for installation in a port or valve chamber, known as the clearance height.