Figure 13: Valid positions of the HydrINS 2/HydrINS 2 Mini flow meter sensor for flow measurement 
 
4.4 
Typical installation of HydrINS 2 / HydrINS 2 Mini flow meters
 
 
Typical installations are as follows: 
 
HydrINS 2: 1" insertion – drill 25 mm (0.98 inches) at least 
 
HydrINS 2 Mini: two possibilities: 
o  Either  1"  insertion  plus  1"-3/4"  adapter  –  drill  25  mm  (0.98  inches)  minimum:  this 
can  measure  the  inside  diameter  of  pipes  using  diameter  gauges  marketed  by 
HYDREKA and adaptable to 1" tappings. 
o  Or 3/4" insertion – drill 19 mm (0.75 inches) minimum: does not need an adapter.  
The  preparation  of  an  insertion  point  compatible  with  HydrINS  2  or  HydrINS  2  Mini  is  exactly  the 
same  as  for  the  preparation  of  a  classic  insertion  point  for  the  installation  of  a  connection.  No 
additional  accessories  are  required.  After  drilling  the  pipe,  tighten  the  HydrINS  2  /HydrINS  2  Mini 
probe to the ball valve.  
 
Position at 1/8 diameter 