Valeport Ltd 0804IDU Manuel D’Utilisation

Page de 83
 
HydrINS 2 / HydrINS 2 Mini flow meter  
Installation Manual  
 
Page 57 / 83 
9  Technical Characteristics:  
9.1   Hydrins II Probe 
Measurement range
 
Two-way, from 0.02 m/s to 5 m/s, limited only by the stability and stiffness of the probe. 
Fluid with conductivity of at least 20 µS/cm.
 
Precision
 
Point speed measurement: at mean or smoothed speed: ±2% if V 
 10cm/s and ±2mm/s with respect to the 
reading if V < 10cm/s. 
Mean speed and volume: refer to the ISO 7145-1982 standard.
 
Units
 
mm, metres, litres, Megalitres, m
3
, feet, ft
3
, ImpGal, USGal, MegaImpGal,  
MegaUSGal, seconds, minutes, hours, days.
 
Electrical power
 
On internal lithium batteries with four-year battery life (for one measurement per minute). Ten-year option. 
 
Sensor identity and parameters
 
Internal calibration, serial number, calibration date, file history.
 
Calibration
 
Performed at the factory on hydraulic bench connected to COFRAC calibration standards.
 
Self-test
 
Via the embedded electronics in accordance with OIML R49 Type P.
 
Internal parameters
 
Volume totalizer in non-volatile memory. Negative / Positive / Net volume 
Several modifiable parameters (unit, period, insertion factor, etc.).
 
Outputs
 
RS 232
 
Configurable for: point speed, mean speed, instantaneous flow rate, volume totalisers.
 
Pulses
 
Two pulse outputs, opto-isolated open collectors Maximum frequency: 50 Hz Pulse width: 10ms - 28V 50 mA 
maximum - Max. impedance 35 Ohms - Typical capacitance: 25 pF 
Possibility: one positive flow channel and one negative flow channel, or one flow channel and one channel for the 
flow direction. 
 
External connector
 
10-pin waterproof military connector.
 
Software
 
Interfaced with Winfluid.
 
Operating temperature
 
Electronics: -20 to +60°C, Inserted part: unfrozen water at +60°C.
 
Maximum operating pressure
 
20 bars - 1/8" BSP pressure fitting, Quickfit connector included.
 
Waterproofing
 
IP68/NEMA6 for immersion at 10 m for 72 hours (with fittings connected).
 
Installation
 
On insertion valve (ball valve) 1" BSP internal free bore diameter 25 mm (1"NPT as an option). Probe anti-
ejection chain.
 
Insertion length
 
300, 500, 700 and 1000 mm.
 
Dimensions
 
Sensor diameter: 22 mm. Stem diameter: 19 mm. 
Head diameter: 130 mm x 100 mm high.
 
Weight
 
< 3.5 kg.
 
Materials used
 
Inserted part:  
316 stainless - grey PVC, WRAS approval No. 0307501. 
Nitrile seals, WRAS approval No. 0470NBR70. 
ACS certification 
External part: Stainless 316 - Bronze CZ 121 - Reinforced ABS housing.
 
Guarantee:
 
36 months.
 
Metrological certification
 
Calibrated using electromagnetic flow meters (100 and 200 mm) calibrated according to COFRAC 
procedures.
 
Gauge
 
Measurement of pipe inside diameters. Standard length 500/700/900.  
Other lengths available as options.