Wavetec FZCO WT-ECF Manuel D’Utilisation

Page de 9
Release Notes Document 
PDU Display Garbage 
  Page 
7 of 8
 
3. T
ESTING 
S
COPE
3.1  Test Environment: 
EQ set-up for 4 counters, with following configuration: 
 2 Bar SDU, in Dual-Line mode – Powered by 5V Adaptor
 1 Cube SDU – Powered by 5V Adaptor
 3 CDU – Powered by Active Hub
 1 PDU – Powered by Active Hub
 1 TDU-Lite – Powered by 12V Adaptor
 2 Hard-TSU – Powered by Active Hub
 1 Soft-TSU – Powered by Active Hub
Configuration Description: 
 PDU acts as CDU
 Bar SDU, Cube SDU and CDU connected with 1 separate Active Hub, with 12V input
power supply.
 Hard TSU and TDU-Lite connected with 1 separate Active Hub, with 12V input power
supply.
 PDU connected with 1 separate Active Hub, with 5V input power supply.
3.2  Test cases & Result: 
S.No. 
Test case 
No. of 
Cycles 
Test Result/Output 
Display on PDU, without any corrupted 
image? 
100 
100/100 - Passed 
All CDUs, PDU & SDUs updated every 
time & correctly? 
100 
100/100 – Passed 
Calling sound always synced with calling? 
100 
100/100 – Passed 
Ticket issuance from TDU Lite 
100 
100/100 – Passed