Wavetec FZCO WT-ECF Manuel D’Utilisation
Release Notes Document
PDU Display Garbage
PDU Display Garbage
Page
7 of 8
3. T
ESTING
S
COPE
3.1 Test Environment:
EQ set-up for 4 counters, with following configuration:
2 Bar SDU, in Dual-Line mode – Powered by 5V Adaptor
1 Cube SDU – Powered by 5V Adaptor
3 CDU – Powered by Active Hub
1 PDU – Powered by Active Hub
1 TDU-Lite – Powered by 12V Adaptor
2 Hard-TSU – Powered by Active Hub
1 Soft-TSU – Powered by Active Hub
1 Cube SDU – Powered by 5V Adaptor
3 CDU – Powered by Active Hub
1 PDU – Powered by Active Hub
1 TDU-Lite – Powered by 12V Adaptor
2 Hard-TSU – Powered by Active Hub
1 Soft-TSU – Powered by Active Hub
Configuration Description:
PDU acts as CDU
Bar SDU, Cube SDU and CDU connected with 1 separate Active Hub, with 12V input
Bar SDU, Cube SDU and CDU connected with 1 separate Active Hub, with 12V input
power supply.
Hard TSU and TDU-Lite connected with 1 separate Active Hub, with 12V input power
supply.
PDU connected with 1 separate Active Hub, with 5V input power supply.
3.2 Test cases & Result:
S.No.
Test case
No. of
Cycles
Test Result/Output
1
Display on PDU, without any corrupted
image?
image?
100
100/100 - Passed
2
All CDUs, PDU & SDUs updated every
time & correctly?
time & correctly?
100
100/100 – Passed
3
Calling sound always synced with calling?
100
100/100 – Passed
4
Ticket issuance from TDU Lite
100
100/100 – Passed