ITK SAS MAST001 Manuel D’Utilisation
7
Technical specifications
The ITK-FlowMaster is the device used to communicate with the ITK-FlowSensor and with a gateway.
Model
ITK-FlowMaster
Dimensions & weight
115x64x29mm
200 grams
Power supply
Power supply from connected gateway through USB port.
Power consumption in standby mode: ~100 µA
Power consumption in emission mode: ~40mA
Power consumption in reception mode: ~20mA
Operating conditions
-20°C to +70°C
Indoor
Shielded Housing
The ITK-FlowMaster electronic board is enclosed in a metal case.
Antenna
The ITK-FlowMaster comes with an external antenna. Antenna is plugged to the ITK-FlowMaster. It
has a 5m wire. Antenna should be placed at 5m above ground to ensure an efficient reception of
radio frequency frames.
Radio Frequency
ISM bands: 902-928 MHz (FCC compliant).
Radio range
Up to 2 miles Loss-Of-Signal with emitting antenna 5m above floor.
Typically 0.5 miles in a vineyard.
Communication protocol
Clover-Net® protocol (private LoRa radio network).
Power consumption in reception mode: ~20mA
Operating conditions
-20°C to +70°C
Indoor
Shielded Housing
The ITK-FlowMaster electronic board is enclosed in a metal case.
Antenna
The ITK-FlowMaster comes with an external antenna. Antenna is plugged to the ITK-FlowMaster. It
has a 5m wire. Antenna should be placed at 5m above ground to ensure an efficient reception of
radio frequency frames.
Radio Frequency
ISM bands: 902-928 MHz (FCC compliant).
Radio range
Up to 2 miles Loss-Of-Signal with emitting antenna 5m above floor.
Typically 0.5 miles in a vineyard.
Communication protocol
Clover-Net® protocol (private LoRa radio network).