innogy SE IEKA160 Manuel D’Utilisation
Technical Information
LSX
30
Property
Value
Signal
Voltage monitor
Execution
Contact input (to GND)
Power supply
internal pull-up resistor
10 kOhm at 5 V DC
10 kOhm at 5 V DC
LOW level
0 … 1 V DC
HIGH level
3.5 … 5 V DC
External voltage resistance
-5 … 30 V DC
Table 54: Technical Information – Connection charging point 2 – Voltage monitor
Property
Value
Signal
Proximity
Execution
Analogue input
Voltage range
0 … 5 V DC
Accuracy
+/-5%
Resolution
10 bit
External voltage resistance
0 … 5 V DC or max. 100 mA
Table 55: Technical Information – Connection charging point 2 – Proximity
Property
Value
Signal
Contactor
Execution
Open drain output (to GND)
Continuous current
max. 1 A
Short-time current (<1 s)
5 A
Electric strength
30 V
Table 56: Technical Information – Connection charging point 2 – Contactor
Property
Value
Signal
Operating current trigger
Execution
Open drain output (to GND)
Continuous current
max. 1 A
Short-time current (<1 s)
5 A
Electric strength
30 V
Table 57: Technical Information – Connection charging point 2 – Operating current trigger