Honeywell 46-00869 Manuel D’Utilisation

Page de 64
 
 
39 
T
ROUBLESHOOTING 
G
UIDE
  
 
The following guide is for reference purposes only. Contact a customer service 
representative to preserve the limited warranty terms on page 54. 
 
 
7820
 
S
ERIES 
T
ROUBLESHOOTING 
G
UIDE
 
SYMPTOMS 
POSSIBLE CAUSE(S) 
SOLUTION 
All Interfaces 
No LEDs, beep 
or motor spin. 
No power is being 
supplied to the 
scanner. 
Check transformer, outlet and 
power strip.  Make sure the 
cable is plugged into the 
scanner. 
 
No LEDs, beep. 
No power is being 
supplied to the 
scanner from host. 
Some host systems cannot 
supply enough current to power 
7820 series scanner.  Use the 
power supply included with the 
scanner. 
 
3 beeps on 
power up. 
Non-volatile RAM 
failure. 
Contact a customer service 
representative, if the unit will not 
hold the configuration. 
 
Continuous 
razz tone on 
power up. 
Diagnostic failure. 
Contact a customer service 
representative, if the unit will not 
function. 
 
Razz tone and 
blue LED flash 
at power up. 
VLD failure. 
Contact a customer service 
representative. 
Scanner motor failure. 
Contact a customer service 
representative. 
 
Multiple scans 
upon 
presentation of 
code. 
Same symbol timeout 
set too short. 
Adjust same symbol timeout for 
a longer time.
 
 
The unit powers 
up but does not 
beep. 
Beeper disabled 
No volume is selected 
No tone is selected. 
Enable beeper. 
Select volume (configurable). 
Select tone.