IBM 81Y4484 Manuel D’Utilisation

Page de 16
ServeRAID M5110 and M5110e SAS/SATA Controllers for IBM System x
6
MegaRAID CacheCade Pro 2.0 SSD caching for traditional hard drives
MegaRAID CacheCade Pro 2.0 read/write software is designed to accelerate the performance of hard 
disk drive (HDD) arrays with only an incremental investment in solid-state drive (SSD) technology. 
The software enables SSDs to be configured as a dedicated pool of controller cache to help maximize 
the I/O performance for transaction-intensive applications, such as databases and web serving. 
CacheCade software tracks data storage access patterns and identifies the most frequently accessed 
data. The hot data is then automatically stored on the solid-state storage devices that are assigned as 
a dedicated cache pool on a ServeRAID controller with the M5100 Series SSD Caching feature 
(90Y4318) enabled.
Technical specifications
The ServeRAID M5110 and M5110e SAS/SATA controllers have the following specifications:
PCI Low Profile, Half-length - MD2 form factor (M5110) or onboard chip (M5110e)
Eight internal 6 Gbps SAS/SATA ports
Two internal Mini-SAS connectors (SFF-8087)
6 Gbps throughput per port
800 MHz dual-core IBM PowerPC® processor with LSI SAS2208 6 Gbps RAID on Chip (ROC) 
controller
PCI Express 3.0 x8 host interface
Support for RAID levels 0, 1, 10 standard; support for RAID 5, 50 and 6, 60 with optional upgrades
Optional onboard data cache (DDR3 running at 1333 MHz) with the choice of: 
512 MB with optional battery backup
512 MB or 1 GB with flash backup (MegaRAID CacheVault technology)
Support for SAS and SATA HDDs and SSDs
Support for intermixing SAS and SATA HDDs and SSDs; mixing different types of drives in the same 
array (drive group) not recommended
Connections to up to 32 internal drives, depending on the server model
Optional support for self-encrypting drives (SEDs) with MegaRAID SafeStore
Optional support for SSD performance acceleration with MegaRAID FastPath and SSD caching with 
MegaRAID CacheCade Pro 2.0
Support for up to 64 virtual drives, up to 128 drive groups, up to 16 virtual drives per one drive group, 
and up to 32 physical drives per one drive group
Support for logical unit number (LUN) sizes up to 64 TB 
Configurable stripe size up to 1 MB 
Compliant with Disk Data Format (DDF) configuration on disk (COD)
S.M.A.R.T. support
MegaRAID Storage Manager management software