IBM 43W9049 Manuel D’Utilisation

Page de 32
IBM Flex System Enterprise Chassis
15
Additional features:
Resource-oriented chassis map provides instant graphical view of chassis resources, including 
nodes and I/O modules
Remote console, including remote keyboard, video, mouse (KVM) session, remotely mounted 
optical and USB media, and remote power control
Hardware detection and inventory creation
Firmware compliance and updates
Automatic detection of hardware failures and alerting. Capability to take corrective action, 
including automatically notifying IBM of problems to escalate problem determination 
Health status, such as CPU utilization, on all hardware devices from a single chassis view
Administrative capabilities, such as setting up users within profile groups, assigning security 
levels, and security governance 
Power supplies
A maximum of six power supplies can be installed in the Enterprise Chassis. Either 2500W or 2100W 
power supplies are available. Two 2500W power supplies are standard in model 8721-A1x. Additional 
power supplies are orderable per the following table. All installed power supplies must be the same.
Table 5. Ordering part number and feature code
Description
Part number System x
Feature code
Power 
Systems
Feature code
IBM Flex System Enterprise Chassis 2500W Power Module
(1 power supply)
43W9049
A0UC
3590
IBM Flex System Enterprise  Chassis 2100W Power Module
(1 power supply)
47C7633
A3JH
None
Each power supply part number (43W9049) ships with one 2-meter (6.5 ft) 16A/100-250V, C19 to IEC 
320-C20 rack power cable.
The following figure shows the power supply and highlights the light-emitting diodes (LEDs).
Figure 10. Power supply option