IBM Flex System x220 Compute Node
28
Light path diagnostics
For quick problem determination when you are physically at the server, the x220 offers a three-step 
guided path:
The Fault LED on the front panel
1.
The light path diagnostics panel, shown in the following figure.
2.
LEDs next to key components on the system board
3.
The x220 light path diagnostics panel is visible when you remove the server from the chassis. The panel 
is located at the upper right side of the compute node, as shown in the following figure.
Figure 11. Location of x220 light path diagnostics panel
To illuminate the light path diagnostics LEDs, power off the compute node, slide it out of the chassis, and 
press the power button. The power button doubles as the light path diagnostics remind button when the 
server is removed from the chassis.
The meanings of the LEDs in the light path diagnostics panel are listed in the following table.
Table 19. Light path diagnostic panel LEDs
LED
Meaning 
LP
The light path diagnostics panel is operational.
S BRD
A system board error is detected.
MIS
A mismatch has occurred between the processors, DIMMs, or HDDs within the configuration (as 
reported by POST).
NMI
A non-maskable interrupt (NMI) has occurred.
TEMP
An over-temperature condition occurs that was critical enough to shut down the server.
MEM
A memory fault has occurred. The corresponding DIMM error LEDs on the system board are also lit. 
ADJ
A fault is detected in the adjacent expansion unit (if installed).