SECTION 2: CIRCUIT REQUIREMENTS
Amperage Draw
The motor for your machine may draw the follow-
ing amps at maximum load.
G0513X at 220V Single-Phase ............. 10 Amps 
G0513X at 110V* .................................. 20 Amps
G0514X at 220V Single-Phase ............. 16 Amps 
G0514X3 at 220V 3-Phase ..................... 9 Amps
G0514X3 at 440V 3-Phase** ............... 4.5 Amps
Circuit Requirements
We  recommend  connecting  this  machine  to  a 
dedicated circuit with a verified ground, using the 
circuit breaker size given below. Never replace a 
circuit breaker with one of higher amperage with-
out  consulting  a  qualified  electrician  to  ensure 
compliance with wiring codes. 
If you are unsure 
about  the  wiring  codes  in  your  area  or  you 
plan to connect your machine to a shared cir-
cuit, you may create a fire hazard—consult a 
qualified electrician to reduce this risk.
G0513X at 220V .............15 Amp Circuit Breaker
G0513X at 110V* ...........30 Amp Circuit Breaker
G0514X ..........................20 Amp Circuit Breaker
G0514X3 at 220V ...........15 Amp Circuit Breaker
G0514X3 at 440V** ........15 Amp Circuit Breaker
To run on 110V, you MUST rewire the motor. 
Refer to the wiring diagram on Page 54.
** To run on 440V, you must rewire the motor 
and replace the 220V magnetic switch assem-
bly with the 440V magnetic switch assembly 
(Part #P0514X3161A). Refer to the wiring dia-
gram on Page 58 for wiring details.
Figure 3. NEMA 6-15 plug and receptacle.
Figure 4. NEMA 5-30 plug and receptacle.
Plug Type
The  cord  set  enclosed  does  not  have  a  plug  as 
the  style  of  plug  you  require  will  depend  upon 
the type of service you currently have or plan to 
install. We recommend using the following plugs 
for your machine on a dedicated circuit only (see 
Figures 3–6 for examples):
G0513X at 220V ....................... NEMA 6-15 Plug
G0513X at 110V* ..................... NEMA 5-30 Plug
G0514X .................................... NEMA 6-20 Plug
G0514X3 at 220V ..................NEMA L15-20 Plug
G0514X3 at 440V** ................NEMA L16-20 Plug