Honeywell ADEMCO LYNXR Series Manuel D’Utilisation

Page de 72
 
–28– 
56 Enhanced Zone Programming Mode 
 
While in Program mode, press 
56 to enter Zone Programming Menu Mode. 
Refer to the zone assignment table for 
56 on the separate programming form. 
The following explains the 
56 prompts in detail. The left two columns identify the prompts and list the 
available entries for each. The right-most column provides a further explanation of the entries. 
Note:  
You may find it convenient to adjust the volume setting before entering the Programming Mode. This will allow you to clearly hear 
feedback announcements or system beeps. 
 
 
 
 
 A  0I
 
Zone number 
01-41, 95, 96, 99 = Zone number 
[✻] = continue 
00 = exit Zone Programming mode
 
Enter the 2-digit zone number to be programmed and the Voice Descriptor 
for the selected zone number will be announced, if it is programmed.  Press 
[
] to advance. 
 Zone 01 = hardwire 
 
 Zones 02-25 = RF zones (only) 
 
 
 Zones 26-41 = Button zones (only)  
 Zone 92 = Duress 
 
 Zones 95, 96, 99 = Panic zones 
 
Pressing 00 exits mode, upon which the prompt “56” blinks, indicating the 
mode is inactive. Press [
] + any field number to go to that field. 
 
 
 
 b
 
zt
 
Zone type 
00-24 = zone type 
[✻] = continue 
[#] = return to previous prompt 
 
Note:  If 00 is accepted as a zone type, save the 00 
zone type and advance to the confirm delete 
prompt (F). 
 
Each zone must be assigned to a zone type, which defines the way in 
which the system responds to faults in that zone. Enter the 2-digit zone 
type for this zone as follows: 
00 = Not Used 
08 = 24 Hr Aux 
01 = Entry/Exit #1 
09 = Fire without verify 
02 = Entry/Exit #2 
10 = Interior w/Delay 
03 = Perimeter 
20 = Arm–Stay 
04 = Interior Follower 
21 = Arm–Away 
05 = Trouble Day/Alarm Night 
22 = Disarm 
06 = 24 Hr Silent 
23 = No Alarm Response 
07 = 24 Hr Audible 
24 = Silent Burglary 
 
 
 
C
 
rc
 
Report code 
Enter the report code for this zone. 
[✻] = continue 
[#] = return to previous prompt 
 
The report code consists of 2 hexadecimal digits, each in turn consisting of 
2 numerical digits. For example, for a report code of "3C", enter [0][3] for 
"3" and [1][2] for "C". 
If this is Zone 1, 95, 96 or 99, the system skips to the VOICE 
DESCRIPTOR prompt (1C). 
 
 
d
 
i
 
Input type 
3 =RF (supervised RF) – sends periodic 
check-in signals, faults, restore and low 
battery signals 
Note:  RF type transmitters must remain within 
range of the receiver, otherwise a 
supervision failure signal will occur. 
4 = UR (unsupervised RF) – sends same as 
“RF” type, but control does not supervise 
the check-in signals 
5 = BR (button type) – sends only fault and low 
battery signals; does not send restores or 
check-in signals 
Note  UR and BR type transmitters may be carried 
off premises (out of range without causing a 
supervision failure. 
[✻] = continue 
[#] = return to previous prompt 
 
Enter the input type for the transmitter assigned to this zone. Refer to the 
transmitter’s instructions for input types of each transmitter. 
 
Note:   Zones 2-25 should be assigned Input Type 3 or 4 . Zones 26-41 
should be assigned Input Type 5 only. 
 
 
 
E
 
l  
 
Loop number or Loop and Serial 
number 
(if using RF Learning) 
1-4 = loop number for the zone of the 
transmitter being entered.  
0 + [✻] = continue to DELETE ZONE 
PARAMETERS CONFIRMATION 
prompt (F) 
[✻] = continue to the ENROLL MODE prompt 
(1A) if not entered, or VOICE 
DESCRIPTOR prompt if already entered 
[#] = return to previous prompt 
 
This prompt can be used to enroll loop number and serial number via RF 
transmission or the loop number can be enrolled manually. If using the 
RF Learning Mode, there is no need to manually enter a loop number. 
Proceed directly to RF Learning 
 
Notes: (1)  BR type devices cannot be enrolled by using UR or RF type. 
Likewise, UR or RF type devices cannot be enrolled by using a 
BR type device. There is a 52-second time-out for RF 
enrolling. At the end of the time-out, the system returns to 
the INPUT TYPE prompt (d). If enrolled, loop number and “L” 
are displayed. 
 
(2) Once encrypted (high-security) devices have been enrolled they 
must be activated. Refer to the device’s Installation 
Instructions to activate the High-Security Mode. 
 
 
Get user manuals: 
See SafeManuals.com