Yuasa Y5-12L Fascicule
Y5-12L
Nominal voltage
12
V
20-hr rate Capacity to 1.75VPC at 20°C
5
Ah
10-hr rate Capacity to 1.75VPC at 20°C
4.63
Ah
Length
90 (±1)
mm
Width
70 (±1)
mm
Height
101 (±1)
mm
(height over terminals)
107 (±2)
mm
Mass (typical)
1.68
kg
FASTON (Quickfit / release)
6.35
mm
Storage
Charge
Discharge
Charge
Discharge
LAYOUT
Capacity loss per month at 20°C (approx)
3
%
Standard Option
Flame retardant option (FR)
Flame retardant option (FR)
13.65 (±1%)
V
2.275 (±1%)
V/cell
Float Charge voltage temperature correction factor
(for variations from the standard 20°C)
(for variations from the standard 20°C)
-3
mV/cell/°C
14.5 (±3%)
V
2.42 (±3%)
V/cell
Cyclic Charge voltage temperature correction factor
(for variations from the standard 20°C)
(for variations from the standard 20°C)
-4
mV/cell/°C
Float charge current limit
No limit
A
Cyclic (or Boost) charge current limit
1.25
A
1 minute
50
A
Internal resistance
N/A
mΩ
3RD PARTY CERTIFICATIONS
Short-Circuit current
N/A
A
ISO 9001 - Quality Management Systems
ISO 14001 - Environmental Management Systems
ISO 14001 - Environmental Management Systems
Measured at 1 kHz
45
mΩ
EN 18001 - OHSAS Management Systems
UNDERWRITERS LABORATORIES Inc.
UNDERWRITERS LABORATORIES Inc.
Refer to the technical manual
YUCEL
STANDARDS
EUROBAT Classification: Standard Commercial
3 to 5
years
IEC61056
Yuasa design life @ 20°C
up to 5
years
ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
Issue No.: V.1 / Issue Date: July 2010
Issue No.: V.1 / Issue Date: July 2010
Yucel-Series - Valve Regulated Lead Acid Battery
-20°C to +60°C
ABS (UL.94:HB)
ABS (UL94:V0)
SPECIFICATIONS
DIMENSIONS
TERMINAL TYPE
OPERATING TEMPERATURE RANGE
STORAGE
CASE MATERIAL
CHARGE VOLTAGE
-20°C to +60°C
-15°C to +50°C
-15°C to +50°C
SAFETY
Float charge voltage at 20°C
Cyclic (or Boost) charge at 20°C
CHARGE CURRENT
MAXIMUM DISCHARGE CURRENT
Installation
Can be installed and operated in any orientation except permanently inverted
Handles
Can be installed and operated in any orientation except permanently inverted
Handles
SHORT-CIRCUIT CURRENT & INTERNAL RESISTANCE
(according to EN IEC 60896-21)
(according to EN IEC 60896-21)
IMPEDANCE
DESIGN LIFE
PERFORMANCE & CHARACTERISTICS
Batteries must not be suspended by their handles (where fitted)
Vent valves
Each cell is fitted with a low pressure release valve to allow gasses to escape and then reseal.
Gas Release
Vent valves
Each cell is fitted with a low pressure release valve to allow gasses to escape and then reseal.
Gas Release
VRLA Batteries release hydrogen gas which can form explosive mixtures in air. Do not place inside a sealed
container
container
YUASA BATTERY SALES UK LTD.
Unit 22
Rassau Industrial Estate
Ebbw Vale, Gwent
NP23 5SD
UK
Unit 22
Rassau Industrial Estate
Ebbw Vale, Gwent
NP23 5SD
UK
Recycling
YUASA's VRLA batteries must be recycled at the end of life in accordance with local and national laws and
regulations
regulations