iStarUSA TC-1U30FX2 Manuel D’Utilisation
Page
7
3.3 Efficiency
80% minimum at 115VAC, 300W Output
3.4 Voltage
Hold-up
Time
All output will stay within regulation for at least 17ms after an AC line voltage
failure is detected at nominal line (115VAC or 230VAC) under 70% full load condition.
3.5 Power
Sequencing
All outputs, regardless of loading, turn on within 50ms of each other. The 5VSB
output is in regulation for a minimum of 10ms prior to the other output rails
reaching regulation.
3.6 Timing / Housekeeping / Control
Figure 1 Power Supply Timing
T1 <
500ms
0.1ms ≦ T2 ≦ 20ms
100ms < T3 < 500ms
T4 ≦ 100Us
T5 ≧ 17
T6 ≧ 1ms
~
~
~
~
VAC_ON
VAC_OFF
PS_ON#
PS_OFF#
95%
10%
PWR_OK
+12VDC
+5VDC
O/P’s
T1
T2
T3
T4
T5
T6
PWR_OK Sense Level=95% of nominal