3.3 Efficiency 
80% minimum at 115VAC, 300W Output 
 
3.4 Voltage 
Hold-up 
Time 
All output will stay within regulation for at least 17ms after an AC line voltage   
failure is detected at nominal line (115VAC or 230VAC) under 70% full load condition. 
 
3.5 Power 
Sequencing 
All outputs, regardless of loading, turn on within 50ms of each other. The 5VSB   
output is in regulation for a minimum of 10ms prior to the other output rails   
reaching regulation. 
 
3.6    Timing / Housekeeping / Control 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 1    Power Supply Timing 
 
 
 
 
                 
 
  T1    <
           
 500ms 
 
           
0.1ms  ≦ T2 ≦  20ms 
 100ms < T3 < 500ms 
                 
     
  T4  ≦  100Us 
T5  ≧  17 
                 
     
  T6  ≧  1ms   
~
~
~
~
VAC_ON 
VAC_OFF 
PS_ON# 
PS_OFF# 
95% 
10% 
PWR_OK 
+12VDC 
 +5VDC    
O/P’s 
T1
T2
T3
T4
T5 
T6 
PWR_OK Sense Level=95% of nominal