Zebra HW46211 Manuel D’Utilisation

Page de 275
Page 4-60
110XiIIIPlus Maintenance Manual
13185L-002 Rev. A  1/24/06
Section 4
Maintenance
7. Refer to 
8. Reconnect all cables to the power supply and verify proper placement and 
orientation.
9. Refer to 
. Reinstall the electronics cover.
10. Reconnect the AC power cord.
11. Turn the printer On (l). Enter Configuration Mode and set the printer to 
Cutter Mode. Save as PERMANENT and turn the printer Off (O). 
12. Load media and ribbon, press and hold PAUSE while turning the printer On (l), and 
run labels through the printer. Test the cutter for proper operation.
13. Reconnect data cables and turn the printer On (l).
Retiming the Upper Drive Arm
If the media hits either cutter blade or if the cutter does not cut through the label material 
completely, the upper drive arm alignment must be checked.
1. Refer to 
. Turn the printer Off (O), remove the AC power 
cord and data cables.
2. Refer to 
 and remove the electronics cover.
3. Refer to 
 and remove the power supply.
4. Hold the upper drive arm in a stationary position and adjust the rotary cutter blade to 
a gap of approximately 0.100 in. (2.5 mm) between the cutting edge on the left end 
and the cutting edge of the rear cutter blade, as shown in 
.
Note • The upper drive arm is part of the cutter mechanical assembly and has 
been aligned at the factory. If the position is altered, the following procedure 
may be used to realign the upper drive arm. The printer must be programmed 
to operate in Cutter Mode prior to performing the following procedure.
Caution:
Unless indicated otherwise, turn the printer Off (O) and disconnect the printer 
from the power source before performing the following maintenance.
Caution:
This installation must be performed by a qualified service technician.