ASSMANN Electronic DK-1621-VH-1 Fiche De Données
Datasheet
Pag 1
DIGITUS NETWORK INSTALLATION CABLE CAT 6 ‐ F/UTP ‐ 250MHz
Application
Primary (Campus), Secondary (Riser), Tertiary (Horizontal)
IEEE 802.3: 10Base‐T; 100Base‐T; 1000Base‐T;
IEEE 802.5 16 MB; ISDN; TPDDI; ATM
IEEE 802.3: 10Base‐T; 100Base‐T; 1000Base‐T;
IEEE 802.5 16 MB; ISDN; TPDDI; ATM
Imprint on cable jacket: DIGITUS CAT6 F‐UTP SOLID CABLE AWG 23/1 LSOH ISO/IEC 11801 EN 50288 TIA / EIA 568‐B.2‐1 WWW.DIGITUS.INFO XXM
Test Standards
TIA/EIA 568‐B.2
ISO/IEC 11801 2nd ed.; IEC 61156‐5
EN 50173; EN 50288‐3‐1
ISO/IEC 11801 2nd ed.; IEC 61156‐5
EN 50173; EN 50288‐3‐1
Flame Resistance
PVC:
IEC 60332‐1
DIGITUS P/N:
LSHF(LSOH):
IEC 60332‐1; IEC 60754‐2; IEC 61034 DIGITUS P/N:
Construction
Conductor
Bare copper wire Ø 0.555± 0.015mm (AWG23)
Insulation
HD Polyethylene, Ø 0.98± 0.03mm
Rip‐cord/Drain wire
Yes, drain wire Ø 0.45mm Tinned‐copper
Shielded
AL Foil
PVC alt. LSHF(LSOH)
Thickness Ø 0.55±0.05mm, External O.D Ø6.0±0.2mm
PVC alt. LSHF(LSOH)
Thickness Ø 0.55±0.05mm, External O.D Ø6.0±0.2mm
Physical Properties
Tensile Strength
≧
13.5Mpa
Elongation
≧
150%
Aging Period
100°C x 24h x7d
Tensile Strength
≧
12.5
Elongation
≧
125
DK‐1621‐V‐1 ; DK‐1621‐V‐305
DK‐1621‐VH‐1 (Orange); DK‐1621‐VH‐305
DK‐1621‐VH‐1 (Orange); DK‐1621‐VH‐305
Sheath
Before Aging
After Aging
Elongation
≧
125
Cold Bending
(‐20 ± 2°C x 4h)
No visible cracks