LOAD REGULATION CHARACTERISTICS
NO.
LOAD
CONDITION
OUTPUT LOAD
12V
+3.3V +5V +12V -12V +5Vsb
1
COND.1
X
X
X
X
4A
2
COND.2
X
X
X
X
3A
3
COND.3
1.5A
1A
1A
0A
0.1A
4
COND.4
26A
1A
8A
0A
0.1A
5
COND.5
1.5A
26A
8A
0A
0.1A
6
COND.6
1A
5A
60A
0A
0.1A
7
COND.7
3.6A 3.6A 2.6A 0.3A
3A
8
COND.8
10A
9A
24A 0.25A
1A
9
COND.9 16.91A 16.91A 49.53A 0.25A 2.48A
10
COND.10
10A 10A 60A 0.3A
3A
Cond. 10 only at 115Vac/60Hz and less then 1 S
Cond. 1 only at 115Vac/60Hz and less then 100 mS
Cond. 1 only at 115Vac/60Hz and less then 100 mS
3.2 REMOTE ON/OFF CONTROL
The power supply shall accept a logic open collector level which will disable/
enable all the output voltage (exclude + 5V standby).
As logic level is low, outputs voltage were enabled.
As logic level is high, outputs voltage were disabled.
enable all the output voltage (exclude + 5V standby).
As logic level is low, outputs voltage were enabled.
As logic level is high, outputs voltage were disabled.
Note: 1. Logic high level: 2.0-5.25V while sourcing 0.2mA maximum.
2. Logic low level: 0-0.5V while sinking 1.6mA maximum.
3. Rise Time: 15ms maximum (10%-90%).
3. Rise Time: 15ms maximum (10%-90%).
3.3 OUTPUT VOLTAGE HOLD-UP TIME
16.0 mS minimum : at 115V / 60 Hz. (80%LOAD)
3.4 OPERATION AT NO LOAD
The power supply shall be capable of being operated with no load on any or
all outputs without damage. For no load on +3.3V & +5V, the output shall not
exceed +4.3V & +6.5Vdc and the power supply may shutdown and require
by remote-control or remove AC power restart.
3.5 PROTECTION
3.5.1 Over-voltage protection
In the event of an over-voltage condition on +3.3 & +5Vdc &+12V the
power supply shall shutdown and require remote control or remove the AC
mains input to reset the system.
power supply shall shutdown and require remote control or remove the AC
mains input to reset the system.
+5V : 6.5V (maximum)
+3.3V : 4.3V (maximum)
+12V : 15.5V (maximum)
+3.3V : 4.3V (maximum)
+12V : 15.5V (maximum)