3.11  Output Transient Response 
Expected output transient step sizes for each output. The transient load slew 
rate is = 1.0 A/µs. 
Table of DC Output Transient Step Sizes 
Output
Max. step size 
(% of rated output amps per Sec 3.1) 
+12V 
10A (10000uF) 
+5 V 
8A (6000uF) 
+3.3 V 
8A (6000uF) 
-12 V 
0.1A (350uF) 
+5 VSB 
0.3A (6000uF) 
(Adding external capactor) 
Output voltages should remain within the regulation limits of Section 3.1, 
and the power supply should be stable when subjected to load transients per 
above table from any steady state load, including any or all of the following 
conditions: 
• Load-changing repetition rate of 50 Hz to 10 kHz 
•AC input range per Section 2.0 
3.12  Capacitive Load 
The power supply should be able to power up and operate normally with 
the following capacitances simultaneously present on the DC outputs. This 
capacitive loading should be used to check all of function test, but without 
hold-up time. 
Output   
ATX12V 
Capacitive load (uF) 
 
0
0
0
0
1
 
V
 
2
1
+
 
0
0
0
6
 
V
 
5
+
 
0
0
0
6
 
V
 
3
.
3
+
 
0
5
3
 
V
 
2
1
-
 
0
0
0
6
 
B
S
V
 
5
+
3.13  Closed-loop Stability 
The power supply shall be unconditionally stable under all 
line/load/transient load conditions including capacitive loads specified in 
Section 3.13. A minimum of 45 degrees phase margin and 10 dB gain margin 
is recommended at both the maximum and minimum loads. 
4.0  Physical Environment 
4.1  Temperature 
4.1.1 Operating Ambient: +0 to 40℃
4.1.2 Non-Operating Ambient(Storage):  -40℃  to +70℃