Spire SilentEagle 750W SP-ATX-750WTB-APFC-2 Manuel D’Utilisation

Codes de produits
SP-ATX-750WTB-APFC-2
Page de 18
 
Version:A/0                                                                                                                                                        Page 7 of 17 
 
Spire Corp.
Http://www.spirepower.com  &  Http://www.spirecoolers.com 
Http://www.spire-corp.com 
 
 
 
 
 
2.2.2 Output DC Current Ranges 
All outputs are within the specified limits of regulation when each output is 
subjected to the conditions listed below. 
Table 3.    DC Input Line Requirements 
DC Nominal Voltage
Minimum 
Current 
Maximum 
Current 
          +12 V1 DC            1 A 
22A 
          +12 V2 DC            1 A 
22A 
          +5 V DC 
          1 A 
28A 
     
           
  +3.3 V DC 
          1 A 
26A 
          -
       
12 V DC 
     0.0 A 
0.5A 
          +5 V SB 
          0.0 A 
2.0A 
NOTE:  
1)The combined power output of +5V and +3.3V shall not exceed 225W. 
The combined power output of +5V,+3.3V and +12V shall not exceed 738W   
2)When +12V,+5V loading max load ,total output power can be 750W whose   
lasting time shall not exceed 15 seconds .The voltage regulation range of any 
output loading surge load shall be +/-10%. 
3)Input voltage is 100-240Vac ,When peak load. 
 
2.2.3 Output Voltage Line Regulation 
The following table specifies line regulation as measured from 
minimum to maximum load including the transient response 
requirements as detailed in this document. 
Table 4.    DC Output Tolerance Specifications 
DC Nominal Output 
Output Voltage Tolerance 
+12V1 DC 
±1% 
+12V 2DC 
±1% 
 +5V DC 
±1% 
+3.3V DC 
±1% 
 -12V DC 
±2% 
  +5V SB 
±1% 
2.2.4 Cross Regulation 
The power supply DC outputs perform within all line and load specifications 
Regardless of the static or transient loads on any of the outputs. 
2.2.5 Efficiency 
80% minimum at 230VAC, 750W output.