Page de 11
6
Hunter Fan Company 
42701-01 • 01/25/06 
7
42701-01 • 01/25/06 
Hunter Fan Company
4 • Wiring the Fan
 
All wiring must be in accordance with national and local electrical 
codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a 
qualified electrician.
Wall switches are not included. Select an acceptable general-use switch in 
accordance with national and local electrical codes.
4-1.  Make sure the power to the outlet box and associated wall switch 
location is still OFF.
    To connect the wires, hold the bare metal leads together and place a 
wire nut over them, then twist the wire nut clockwise until tight.
     
 CAUTION:  Be sure no bare wire or wire strands are visible after 
making connections.
    Connect the wires as follows:
• e bare or green ground wire from the ceiling to the green 
ground wire from the ceiling plate and the green ground wire 
from the fan
• e white wire from the ceiling to the white wire from the fan
• e black wire from the ceiling to the black and the black/white 
wire from the fan 
4-2.  Push all wires and wire nuts into the outlet box.
Single Switch Wiring
Wire Nut