Eveready 1209 Fiche De Données

Page de 2
6V
SUPER HEAVY DUTY
Chemical System:
Zinc-Manganese Dioxide (Zn/MnO 
2
)
(No Added Mercury or Cadmium)
Designation:
ANSI-908D, IEC-4R25
Battery Voltage:
6.0 Volts
Operating Temp:
-18ºC to 55ºC (0ºF to 130ºF)
Average Weight:
600 grams (21.2 oz.)
Volume:
492 cubic centimeters (30 cubic inch)
Average Capacity: 11 Ah to 0.8 volts / cell
(Rated at 25mA continuous at 21ºC)
Cell:
Four No. 60 (size "F") in series
Jacket:
Plastic 
Terminal:
Coil Spring
INTERNAL RESISTANCE VS. TEMPERATURE
The measurement is an approximation of the
battery's actual internal resistance. It is sensitive
to the loads and operator technique.
Schedule: Background Load 600 ohms
Pulse Load 10 ohms
Pulse Duration 1 second
10.0
Eveready 1209
Important Notice
This data sheet contains information specific to batteries manufactured at the time of its publication. 
 Contents herein do not constitute a warranty.
45ºC (113ºF)
Temperature
21ºC (70ºF)
Industry Standard Dimensions
Typical Ri (ohms)
0.7
0.9
1.0
mm (inches)
0ºC (32ºF)
-21ºC (-4ºF)
THIS BATTERY WILL PASS FREELY THROUGH A
CYLINDRICAL TUBE 82.6 DIAMETER x 101.6 LONG.
1
10
100
1000
1
10
100
1000
Se
rv
ic
e
, H
o
u
rs
Discharge Resistance, Ohms
CONSTANT RESISTANCE PERFORMANCE
Typical Service
3.0 Cutoff Voltage
4.4 Cutoff Voltage 
5.2 Cutoff Voltage
1
10
100
1000
1
10
100
1000
Se
rv
ic
e
Hou
rs
Discharge Current, mA
CONSTANT CURRENT DISCHARGE
Typical Service
3.0 Cutoff Voltage
4.4 Cutoff Voltage 
5.2 Cutoff Voltage
1-800-383-7323 USA/CAN
www.energizer.com
PRODUCT DATASHEET
Form No. EBC - 3107F
Page 1 of 2