Installing the Gigaset HC450 door intercom system
Gigaset HC450 / en / A31008-M1799-R101-1-7619 / Starting.fm / 13.02.2007
Ve
rs
ion 4,
 16
.09.
2005
Connecting entry lighting
If you want to use the bottom doorbell key 
to switch on the entry lighting, the light 
source must be connected to the control 
unit using two cores (see illustration 
below). The entry lighting can also be 
switched on/off by means of a switch con-
nected in parallel (see sketch, e.g. motion 
detector). Alternatively, a sensor input 
from a timing circuit can also be 
connected.
Connection with the power supply unit
Connect the mains adapter with the plug 
on the right-hand side of the control unit 
and insert the plug-in power supply unit 
into a socket.
Caution:
– The entry light may only be installed by a 
qualified electrician.
– Installation work on the control unit must 
only be carried out after the current-carry-
ing devices have been disconnected from 
the 230 V mains. Please ensure that the 
mains voltage is not switched on again 
until the installation work has been com-
pleted.
– Stranded conductors must not be used for 
the connection and the insulation on the 
leads must not be stripped by more than 6 
mm. The shrinkage tubes supplied must be 
pulled over the two wires (see diagram).
≤ 6 mm
Thermal
 
shrinkage
 
tubes
Control unit
Entry lighting
230 V mains
Actuator
Pushbutton
Li
ght
ETS
N
L