Eaton Sola 210 210-26-725-00 Manuel D’Utilisation

Codes de produits
210-26-725-00
Page de 4
1
Eaton's Sola ferroresonant products are proven 
technology. In 1938, Sola was awarded the first patent 
for ferroresonant power conditioners: the constant 
voltage transformer. Since then, our technology has 
remained at the forefront of ferroresonant power 
conditioning. 
Today, Eaton's Sola ferroresonant power conditioners 
supply sinewave output, which is  especially important 
for computer applications. 
Whether you purchase a model 200, 210 or 26 voltage 
regulator, you can count on an average of 25 years 
service from your unit. 
Every ferroresonant power conditioner is manufactured 
to exacting specifications and is subject to rigorous 
quality control. 
The ferroresonant power conditioners protect 
equipment from all power problems, other than the 
complete loss of power. They excel at tightly regulating 
the voltage, providing superior noise attenuation and are 
ruggedly designed to withstand the harshest electrical 
environments. 
Possessing no moving parts, ferroresonant power 
conditioners are virtually maintenance free.
What is Ferroresonance?
Simply put, ferroresonance is the property of a 
transformer design in which the transformer contains 
two (2) separate magnetic paths with limited coupling 
between them. The output contains a parallel resonant 
tank circuit and draws power from the primary to 
replace the power delivered to the load.
Note that "resonance" in ferroresonance is similar to 
that in linear circuits with series or parallel inductors 
and capacitors, where the impedance peaks at a 
particular frequency. In a non linear circuit, such as 
a ferroresonant transformer, "resonance" is used to 
reduce the changes in supply voltage and provide more 
constant voltage to the load.
A magnetic device is non linear. Its reluctance changes 
abruptly above a certain magnetic flux density. At 
this point, the magnetic device is defined as being in 
saturation. 
The design of the  ferroresonant transformer allows 
one magnetic path to be in saturation, while the other 
is not. As a result, further change in the primary voltage 
will not translate into changes in the saturated, or 
secondary voltage, and voltage regulation results.
Features and Benefits
•  Superior Low Line Performance
   Specified performance is maintained for all loads    
0 - 100% of nominal rating.
•  Switchmode Computer Load Compatibility
   Able to support typical computer loads when input 
supply mains voltage is 50% below nominal.
•  240 Volt, 230 Volt or 220 Volt Models
    Separate models to suit different nominal supplies or 
particular nominal output voltage requirements.
•  200% Overload Rated
   Suitable for use with computer start up overloads. 
Units are output short circuit proof.
•  On Site Configuration
   7.5 to 18kVA units can be site configured as Single 
Phase or Three Phase operation, if required.
•  Selectable Voltages
   Hardwired 26 Series units have selectable input and 
output voltages.
  5 Year Warranty
   Exceptional MTBF (Mean Time Between Failure), 
an optimum combination of performance to cost 
effective power conditioning.
Typical Model 200 or 210 Performance
Power Conditioners and Voltage Regulators
Sola Power Conditioners
www.eaton.com/powerquality