Finisar FTLF-8524-P2BNL Manuel D’Utilisation

Page de 12
FTLF8524P2xNy Pluggable SFP Product Specification – June 2009 
 
 
© Finisar Corporation Jun 25, 2009 Rev.J 
 
Page 2 
I. 
Pin Descriptions  
 
Pin Symbol 
Name/Description 
Ref. 
1 V
EET 
Transmitter Ground  (Common with Receiver Ground) 
2 T
FAULT
 
Transmitter Fault.  
 
3 T
DIS
 
Transmitter Disable. Laser output disabled on high or open. 
MOD_DEF(2) 
Module Definition 2. Data line for Serial ID. 
MOD_DEF(1) 
Module Definition 1. Clock line for Serial ID. 
MOD_DEF(0) 
Module Definition 0. Grounded within the module. 
Rate Select 
Open or Low = 
 
High = 
1.063 Gb/s or 2.125 Gb/s Fibre Channel, 1.25 Gb/s 
Gigabit Ethernet (Low Bandwidth) 
2.125 or 4.25 Gb/s Fibre Channel  (High Bandwidth) 
 
LOS 
Loss of Signal indication.  Logic 0 indicates normal operation. 
9 V
EER 
Receiver Ground  (Common with Transmitter Ground) 
10 V
EER 
Receiver Ground  (Common with Transmitter Ground) 
11 V
EER 
Receiver Ground  (Common with Transmitter Ground) 
12 RD-
 
Receiver Inverted DATA out.  AC Coupled 
 
13 
RD+ 
Receiver Non-inverted DATA out.  AC Coupled 
 
14 V
EER 
Receiver Ground  (Common with Transmitter Ground) 
15 V
CCR
 
Receiver Power Supply 
 
16 V
CCT
 
Transmitter Power Supply 
 
17 V
EET 
Transmitter Ground  (Common with Receiver Ground) 
18 
TD+ 
Transmitter Non-Inverted DATA in.  AC Coupled. 
 
19 TD-
 
Transmitter Inverted DATA in.  AC Coupled. 
 
20 V
EET 
Transmitter Ground  (Common with Receiver Ground) 
 
 
Notes: 
1.  Circuit ground is internally isolated from chassis ground. 
2.  Laser output disabled on T
DIS
 >2.0V or open, enabled on T
DIS
 <0.8V. 
3.  Should be pulled up with 4.7k – 10kohms on host board to a voltage between 2.0V and 3.6V. 
MOD_DEF(0) pulls line low to indicate module is plugged in. 
4.  For Rate Selectable version only:  In accordance with SFF Committee SFF-8079 Draft Rev. 1.6, 
Table 3.  Note that rate select can also be set through 2-wire bus in accordance with SFF-8472
5
 at Bit 
3, Byte 110, Address A2h (note: writing ‘1’ selects full bandwidth operation).  Rate select is the logic 
OR of the input state of Rate Select Pin and 2-wire bus.  Non Rate Selectable version can operate at 1x, 
2x, 4x Fibre Channel independent of rate select pin setting. 
5.  LOS is open collector output.  Should be pulled up with 4.7k – 10kohms on host board to a voltage 
between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal. 
 
VeeT
VeeT
VeeR
VeeR
TD-
TD+
RD+
RD-
VccT
VccR
VeeT
VeeR
TXFault
MOD-DEF(2)
MOD-DEF(1)
MOD-DEF(0)
Rate Select
LOS
1
2
3
4
5
6
7
8
9
10
20
19
18
17
16
15
14
13
12
11
Towards
ASIC
Towards
Bezel
TX Disable
VeeR
 
 
Diagram of Host Board Connector Block Pin Numbers and Names