ABUS FU8310 Fascicule

Page de 1
Secvest 2WAY Wireless Fire Alarm Button
Art. no. FU8310
•  Convenient surface mounting
•  Tamper monitoring
•  Thermoplastic material
•  Tamper monitoring
The Secvest 2WAY wireless fire alarm button is a detector of the Secvest (or the Terxon with a wireless expansion
module). By pressing the button, you can easily and quickly trigger a fire alarm. In the Secvest, the wireless fire
button assigns a zone with the "fire" characteristic. This zone is monitored and the button will trigger an alarm
even when the alarm panel is disarmed. In the system settings of the Secvest, you can define whether a call
should be made to an emergency call center in addition to the acoustic and visual alarm. With corresponding
batteries (3V lithium) the wireless fire button has a service life of approx. 24 months. The range is approx. 30
meters.
Technical Data:
Dimensions
(WxHxD) 85x85x52 mm
Battery type
3V CR2477N lithium battery 
Width
85 mm
Radio frequency
868,6625 MHz
Transmission power
10 
Housing material
Thermoplastic material 
Height
85 mm
Length
52 mm
Max. battery life
2 year(s)
Max. operating
temperature
50 °C
Max. sending range
(outdoors)
100 m
Max. sending range
(building)
30 m
Min. operating
temperature
-10 °C
Modulation
FM FM / AM
Net weight
0.16 kg
Tamper monitoring
Yes 
IP protection class
32 
Security level
Voltage monitoring
Yes 
DC voltage supply
3 V
Environmental class
II 
Page 1 of 1
Technical alterations reserved. Misprints and errors excepted. Copyright. © ABUS 12/2014