    Printer Setting and Control
035
*
*   
The USB Host port on ‘’i’’ ‘’x’’ model printer is without ‘’HUB’’ function.
*
  The USB Memory Stick supports with ‘’FAT32’’Disk Format and up to 32GB only. The certified venders are Transcend,
      Apacer, Patriot, Consair and Kingston.
*    The download function for Graphic, Font, Label Format, DBF and Command files is operated by GoLabel of PC and
     must go through the a ‘’i’’ ‘’x’’ model printer itself.
*   On a PC, user may copy entire folder’’\LABELDIR’’ from USB memory stick to PC or vice-versa. Copy a sub-folder or 
     individual file in ‘’\LABELDIR’’ to PC or vice-versa is not supported.
USB Keyboard
  
When plug-in an USB keyboard to the printer, LCD panel will display “Standalone Mode”, press the “Enter” key 
     on keyboard and “Feed” key in the printer to entering to the dialog for “Recall Label” operation.
  
Only the sub-dialog “Recall Label” is able operating by keyboard as follow definition:
     1.  Press “ESC” key to exist from “Standalone Mode” or back to previous dialog  
     2.  Press “F1”, it will let the printer from “Ready” mode entering into “Standalone Mode”       
     3.  Press “Enter”, “Arrow” and “Alphabetic” keys as the usual in PC that will perform the key-in function of 
          “Recall Label” in “Standalone Mode”.
Scanner
  
When plug-in an USB scanner to the printer, LCD panel will display “Standalone Mode”, press the “Feed” key 
     in the printer to entering the dialog of “Recall Label” operation. User performs the “Recall Label” function interactively 
     through the LCD panel, 4 direction keys, Feed key and Scanner.
  
Scanner is using in “standalone Mode” to scanning the “Serial Number, Variable” and Print Quantity while the printer
     prompts a message on LCD panel and wait for data input.