Conrad Energy Rechargeable AA Battery x4 pc(s) NiZn 1.6V 252000 Fiche De Données

Codes de produits
252000
Page de 7
 
Conrad Electronic SE  · Klaus-Conrad-Str.1 · 92240 Hirschau 
H
D
D
1
H
1
(6)The outer case of battery , after tin-plated processing, the place is a little soft . For example, in 
the battery use process,  it is normal that the battery shell base presents the scratch.  The 
determination standard should be taken the bilateral consultation as a standard. 
 
 
3
.Measurement & Dimensions 
to see the drawing: 
 
D 14.5-0.7 
mm 
H 51.0-1.0 
mm 
 
 
4. TEST  
4.1 Test conditions: 
  4.1.1  The battery to be tested is the product within one month after being received by customer.  
4.1.2  Ambient conditions: 
                   Temperature                                +20 ±5  
                    Humidity                                     +65%±20% 
4.2 Testing Tools  
4.2.1 Voltage meter:  
0.5 level or higher as required in IEC51/IEC485. Internal impedance exceeds 10KΩ/V. 
4.2.2 Current meter:  
0.5 level or higher as required in IEC51/IEC485. Internal impedance should be less than 
0.01Ω/V(including wires). 
4.2.3. Micrometer caliper:  
With precision of 0.02mm. 
4.2.4. Internal impedance meter:  
Alternating current of 1000HZ, connector measuring equipment with sin wave of 4. 
4.2.5: Impedance loaded meter:  
Value of impedance is with +5% error allowed (including external wires). 
 
4.3 Test methods and benchmarks  
Items Test 
Methods Benchmarks 
1
.Appearance:  —  eyeballing 
—  batteries shall be free from 
any stains; scratches or 
deformations, which may 
reduce the commercial value 
when visually inspected 
2
.Size: 
—  caliper measurement
。 
—  The size shall comply with the 
specified size as the attached 
drawing  
3
.Insulate 
impedance 
—  measured with a Megger  overpack 
and battery electrode between the 
degree of insulation
。 
—  outer sleeve shall exceed   10  
。