Rigol MSO1074Z-S 4-channel oscilloscope, Digital Storage oscilloscope, MSO1074Z-S Manuel D’Utilisation
![Rigol](https://files.manualsbrain.com/attachments/4ef153c5b3a9e56ac40ea738ae281ea9dc808cdc/common/fit/150/50/a84f25c70c016e6b8d8e8d0fbe042c3bbe7b8a8feeee0ecbbc25ec79cb57/brand_logo.gif)
Codes de produits
MSO1074Z-S
RIGOL
2-94
DS1000Z Programming Guide
:TRIGger:SLOPe:BLEVel
Syntax
:TRIGger:SLOPe:BLEVel <level>
:TRIGger:SLOPe:BLEVel?
:TRIGger:SLOPe:BLEVel?
Description
Set or query the lower limit of the trigger level in slope trigger,The unit is the same as the
current amplitude unit.
current amplitude unit.
Parameter
Name
Type
Range
Default
<level> Real
(± 5 × VerticalScale from the screen center) -OFFSet 0
Explanation
. For OFFSet, refer
Return
Format
The query returns the lower limit of the trigger level in scientific notation.
Example
:TRIGger:SLOPe:BLEVel 0.16 /*Set the lower limit of the trigger level to 160mV*/
:TRIGger:SLOPe:BLEVel /*The query returns 1.600000e-01*/
Related
Command