Rigol MSO1074Z-S 4-channel oscilloscope, Digital Storage oscilloscope, MSO1074Z-S Manuel D’Utilisation
Codes de produits
MSO1074Z-S
RIGOL
2-116
DS1000Z Programming Guide
:TRIGger:SHOLd:PATTern
Syntax
:TRIGger:SHOLd:PATTern <pattern>
:TRIGger:SHOLd:PATTern?
:TRIGger:SHOLd:PATTern?
Description
Set or query the data type in setup/hold trigger.
Parameter
Name
Type
Range
Default
<pattern>
Discrete
{H|L}
H
Explanation
H: high level
L: low level
Return
Format
The query returns H or L.
Example
:TRIGger:SHOLd:PATTern L
:TRIGger:SHOLd:TYPe
Syntax
:TRIGger:SHOLd:TYPe <type>
:TRIGger:SHOLd:TYPe?
:TRIGger:SHOLd:TYPe?
Description
Set or query the setup type in setup/hold trigger.
Parameter
Name
Type
Range
Default
<type>
Discrete
{SETup|HOLd|SETHOLd}
SETup
Explanation
SETup: set the time that the data stays stable and constant before the clock edge
appears (
).
HOLd: set the time that the data stays stable and constant after the clock edge
appears (
).
SETHOLd: set the time that the data stays stable and constant before and after the
clock edge appears (
and
).
Return
Format
The query returns SET, HOL or SETHOL.
Example
:TRIGger:SHOLd:TYPe SETHOLd
Related
Command