  DS1000Z Programming Guide 
:TRIGger:SHOLd:PATTern 
Syntax 
:TRIGger:SHOLd:PATTern <pattern> 
:TRIGger:SHOLd:PATTern? 
Description 
Set or query the data type in setup/hold trigger. 
Parameter 
Name 
Type
 
Range
 
Default
 
<pattern>
 
Discrete
 
{H|L}
 
H
 
 
Explanation 
H: high level 
L: low level
 
Return 
Format 
The query returns H or L.   
Example 
:TRIGger:SHOLd:PATTern L 
 
 
:TRIGger:SHOLd:TYPe 
Syntax 
:TRIGger:SHOLd:TYPe <type> 
:TRIGger:SHOLd:TYPe? 
Description 
Set or query the setup type in setup/hold trigger. 
Parameter 
Name 
Type 
Range 
Default 
<type> 
Discrete 
{SETup|HOLd|SETHOLd} 
SETup 
 
Explanation 
  SETup: set the time that the data stays stable and constant before the clock edge 
appears (
).   
  HOLd: set the time that the data stays stable and constant after the clock edge 
appears (
).   
  SETHOLd: set the time that the data stays stable and constant before and after the 
clock edge appears (
)
 
Return 
Format 
The query returns SET, HOL or SETHOL.   
Example 
:TRIGger:SHOLd:TYPe SETHOLd 