:MASK:CREate
Syntax
:MASK:CREate
Description
Create the pass/fail test mask using the current horizontal adjustment parameter and
vertical adjustment parameter.
Explanation
This command is valid only when the pass/fail test is enabled (
) and not in
run state (
).
Related
Command
:MASK:PASSed?
Syntax
:MASK:PASSed?
Description
Query the number of the passed frames in pass/fail test.
Return
Format
The query returns an integer.
:MASK:FAILed?
Syntax
:MASK:FAILed?
Description
Query the number of the failed frames in pass/fail test.
Return
Format
The query returns an integer.
:MASK:TOTal?
Syntax
:MASK:TOTal?
Description
Query the number of the total frames in pass/fail test.
Return
Format
The query returns an integer.
:MASK:RESet
Syntax
:MASK:RESet
Description
Reset the numbers of the passed frames, failed frames and total frames in pass/fail test to
0.
Related
Command