Rigol DS1074Z 4-channel oscilloscope, Digital Storage oscilloscope, DS1074Z Manuel D’Utilisation
Codes de produits
DS1074Z
RIGOL
DS1000Z User’s Guide
2-2
To Enable the Channel
DS1000Z provides 4 analog input channels (CH1-CH4) and each channel can be
controlled independently. As the vertical system setting methods of the 2 channels
are completely the same, this chapter takes CH1 as an example to introduce the
setting method of the vertical system.
Connect a signal to the channel connector of any channel (for example, CH1) and
then press CH1 in the vertical control area (VERTICAL) at the front panel to enable
CH1.
Screen:
The channel setting menu is displayed at the right side of the screen and the channel
label at the bottom of the screen (as shown in the figure below) is highlighted. The
information displayed in the channel label is related to the current channel setting.
After the channel is turned on, modify the parameters such as the vertical scale, the
horizontal time base and the trigger mode according to the input signal to make the
waveform display easy to observe and measure.