Voltcraft VC850 Digital Multimeter with Software included 6000 counts CAT IV 600V, CAT III 1000V VC850 Fiche De Données

Codes de produits
VC850
Page de 2
GENERAL SPECIFICATIONS
SYMBOL: 
6000 counts 
MEASURING RATE:
 Approx. 3 measuring operations/second 
MEASURING LINE LENGTH: 
 
Approx. 90 cm each 
WORkING CONDITIONS:
 0 to 30°C (<75 %rF), 30 to 40°C (<50 %rF) 
OPERATING ALTITUDE:
 
max. 2,000 m  
STORAGE TEMPERATURE:
 -10°C to +50°C 
BASIC ACCURACY:
 ± 5 % 
VOLTAGE SUPPLY:
 9 V block 
battery 
OVER-VOLTAGE CATEGORY:
 CAT III 1,000 V, CAT IV 600 V, contamination degree 2  
WEIGHT: 
Approx. 380 g 
DIMENSIONS (W x H x D): 
185 x 91 x 43 (mm)
         
TECHNICAL DATA
Functions
Range
Resolution
Accuracy 
±
(a% reading + b digits)
Overload 
protection
DCV
600 mV
0.1 mV
±(0.5 % + 3)
1000 V
Impedance: 10 MΩ
6 V / 60 V / 600 V
1 mV / 10 mV / 100 mV
±(0.5 % + 2)
1000 V
1 V
±(0.8 % + 3)
ACV
1
6 V / 60 V / 600 V
1 mV / 10 mV / 100 mV
±(0.8 % + 3)
Frequency range 45 – 400 Hz; 
Overload protection 750 V.
750 V
1 V
±(1.0 % + 5)
DCA
600 μA / 6 mA / 60 mA / 600 mA 0.1 μA / 1 μA / 10 μA/ 100 μA
±(0.8 % + 3)
Fuse, measuring time limit > 5 A: 
max. 10 s with 10 min break.
6 A / 10 A
1 mA / 10 mA
±(1.2 % + 5)
ACA
2
600 μA / 6 mA
0.1 μA / 1 μA
±(1.0 % + 2)
Fuse, measuring time limit > 5 A: 
max. 10 s with 10 min break.
Frequency range 45 – 400 Hz; 
Overload protection 750 V.
60 mA / 600 mA
10 μA / 100 μA
±(1.2 % + 3)
6 A / 10 A
1 mA / 10 mA
±(1.5 % + 5)
Ω
600 Ω
0.1 Ω
±(0.8 % + 3)
w/ REL function
Overload protection 1,000 V; 
Measuring voltage: Approx. 
0.4 V.
6 kΩ / 60 kΩ / 600 kΩ
1 Ω / 10 Ω / 100 Ω
±(0.8 % + 2)
6 MΩ
1 kΩ
±(1.2 % + 2) 
≥ 20 MΩ: 
±(1.5 % + 5)
60 MΩ
10 kΩ
Capacity
40 nF
0.01 nF
±(3.0% + 5) 
with RELfunction
Overload protection 1,000 V
400 nF
0.1 nF
4 μF
1 nF
40 μF
10 nF
±(3.0 % + 5) 
400 μF
100 nF
±(4.0 % + 5) 
4000 μF
1 μF
Not Specified
Frequency / 
Duty Cycle
3
10 Hz to 10 MHz
0.001 Hz to 0.01 MHz
±(0.1 % + 3)
Overload protection 750 V
0.1 to 99.9 %
0.1 %
Not specified
Temperature
4
-40 to -20
º
C
º
C
-(8.0 % +5)
-20 to 0 
º
C
±(1.2 % + 4) 
0 to +100 
º
C
±(1.2 % + 3)
+100 to +1000 
º
C
±(2.5 % + 2)
Diode test
Approx. 3.7 V
0.001 V
NA
Overload protection 1000 V
Acoustic 
continuity 
tester
 <30 Ω continuous sound, test voltage: approx. 0.65 V/DC;.
Overload protection 1,000 V
1.  TrueRMS: Crest factor: max. 3.0.  Permissible display error with an open measuring input: 2 counts. Perissible display error with a short-circuited measuring input: 20 counts.
2. TrueRMS: Crest factor: max. 3.0 (at 750 V max. 1.5)
3. Sensitivity: 200 mV; Amplitude max. 5 Veff (>5 V with adjustable impedance)
4. Without sensor tolerence.
PACkAGE CONTENT
Unit // Batteries // Operating instructions
This data sheet is published by Voltcraft®, Lindenweg 15, D-92242 Hirschau / Germany, Phone +49 180 586 582 7. The data sheet reflects the current 
technical specifications at time of print. We reserve the right to change the technical or physical specifications.
© Copyright 2010 by Voltcraft®.