Insulation Resistance Test 250 V / 500 V (R
ISO
)
The insulation resistance test measures the resistance of the insulation between:
L/N terminals of test socket and PE terminal of test socket in parallel with
L/N terminals of test socket and PE terminal of test socket in parallel with
PROBE 2 (at class I and class II). L/N terminals are shorted by the tester for this
test.
test.
Test probe PROBE 1 and test probe PROBE 2 (at class III).
Warnings
The test voltage is either 500 V (or 250 Vd.c. at GT-800 only). Do not
touch the appliance during the insulation test! If the test fails, any metal
part of the appliance could become live!
part of the appliance could become live!
Always make sure that the test has completed before disconnecting the
appliance leads to ensure that all capacitances have discharged!
Cautions
Do not perform the Insulation test on appliances that failed the
protective bonding test or the visual inspection test.
The insulation test may not be suitable for some types of appliances. For
these appliances an alternative test may be conducted such as touch
current, protective conductor current or substitute leakage current test.
It is essential to refer to the local appliance test standards and/or
reference material for the safe applicability of these alternative tests.
current, protective conductor current or substitute leakage current test.
It is essential to refer to the local appliance test standards and/or
reference material for the safe applicability of these alternative tests.
Test voltage of 500 V may not be suitable for some appliances that
contain overvoltage protection devices (e.g. varistors) in its installation.
For these appliances test voltage of 250 V shall be used, refer to the
local appliance test standards and/or follow the manufacturer
recommendations.
For these appliances test voltage of 250 V shall be used, refer to the
local appliance test standards and/or follow the manufacturer
recommendations.
Remarks:
Connect the appliance and the test lead according to the figure 9, 10 or 11.
For class I appliances no probe is required except if there are some metal
Connect the appliance and the test lead according to the figure 9, 10 or 11.
For class I appliances no probe is required except if there are some metal
parts on the appliance which are not connected to PE terminal.
For class II appliances apply the test probe to any exposed metalwork on the
appliance. Do the test for all exposed metal parts on the appliance, partial
results must pass pre-set limit value.
results must pass pre-set limit value.
Figure 9: Insulation resistance test connections at appliance class I