Beha Amprobe GT-800 STD KITVDE-tester 4472062 Manuel D’Utilisation

Codes de produits
4472062
Page de 76
GT-600/GT-800 Instruction Manual 
63 
 
 
Reset of the GT-600/GT-800 Tester 
 
There are many adjustable parameters in the GT-600/GT-800 Tester. If an 
operator due to any reason wishes to reset all adjustable parameters to factory-
set values, this operation can be done by performing RESET function. 
 
  Switch off the GT-600/GT-800 Tester by using the mains switch (4). 
  Press and keep pressing the function key SAVE (F5) while switching on the GT-
600/GT-800 Tester by using the mains switch (4). 
  “RESET” information will be displayed for a while informing the operator the 
RESET function has been carried out. 
  Release the function key SAVE (F5). 
 
The following parameters have been reset. 
 
Function Parameters
R
PE
 
-
  Test current 5 A
-
  Limit value 0.3 
 
-
  MAN mode 
-
  No test lead compensation 
R
ISO
 
-
  Test voltage 500 V
-
  Protection class I 
-
  Limit value 1.00 M
 (PC I) 
-
  Limit value 0.30 M
 (PC I-HEATER) 
-
  Limit value 2.00 M
 (PC II) 
-
  Limit value 0.25 M
 (PC III) 
I
SUB
 
-
  Protection class I
-
  Limit value 3.50 mA (PC I) 
-
  Limit value 0.50 mA (PC II) 
I
PE(
)
 
-
  Positive mains polarity
-
  Limit value 3.50 mA 
I
T
 
-
  Positive mains polarity
-
  Limit value 0.50 mA 
CLAMP (GT-800 only) -
  Range 0 ... 60 A
PRCD/CORD (GT-800 only) -
  CORD
CORD -
  No cable compensation
-
  Limit value 0.30 
 
PRCD (GT-800 only) -
  No cable compensation
-
  Limit value 0.30 
 
-
  I
N
 = 30 mA 
PELV/SELV -
  PELV
PELV 
-
  Limit value 50 V
SELV 
-
  Limit value 50 V
AUTO (GT-800 only) -
  Selected AUTO test No. 145 (German region) 
MENU -
  Operator XXXX
-
  Measurement times  
-
  MAN, MAINS ... 10 seconds 
-
  MAN, MAINS FREE ... 3 seconds 
-
  AUTO, MAINS ... 10 seconds 
-
  AUTO, MAINS FREE ... 3 seconds 
-
  Region GERMANY  
-
  Acoustic signal ON 
-
  Barcode reader mode STANDARD 
-
  Language GERMAN 
-
  Contrast 50 %