67 
 
 
Technical Specifications 
 
 
General Features 
Standards used 
VDE 0701-0702, DIN VDE 0404-1/-2, EN 61010-1, 
 
EN 61557-2, 4 
Power supply (fixed mains cord)  230 V +10%/-15%, 50/60 Hz 
Max. inter. power consumption  45 VA (R
PE-5A
 function) 
Max. load output current 
  16 A 
Display 
Graphic LCD 128x64 dots with blue backlight 
Function selection 
10-position rotary switch 
Result limits 
Adjustable, refer to the adjustment range in  
 
each function (visual and acoustic signal in case  
 
of exceeded value) 
Memories 
3.896 locations, two levels (client and 
 
appliance), additional entry for site, location 
 and 
description 
Memory occupation 
Each stored result (except PRCD and AUTO  
 
function) ... 2 locations 
 
Each PRCD stored result ... 3 locations 
 
Each AUTO function stored result ... number of 
 
measurements + 1 location 
 
Each Client ... 4 locations 
 
Each Appliance ... 3 locations 
Buzzer for acoustic signal 
Built in 
Real time clock (RTC) 
Built in 
Internal battery for RTC 
Li 3V/230 mAh type IEC CR2032 
USB 2.0 communication with PC  Yes 
USB Bar code reader connection  Yes 
USB Keyboard connection 
Yes 
USB Stick connection 
Yes 
Protection class 
I (PE conductor) 
Measurement time: 
  Single mains-free meas. 
Adjustable 3 ... 60 s 
  Single mains supplied meas. 
Adjustable 10 ... 299 s 
  Continuous measurements  
Limited to 5 minutes (save function active) 
  AUTO mains-free meas. 
Adjustable 3 ... 60 s 
  AUTO mains supplied meas. 
Adjustable 10 ... 299 s 
Protection against mains  
socket overload 
Fuses F1 and F2, T16 A (H) / 250 V, 5×20 mm 
Protection against excessive 
protective conductor current 
No, installation RCD trips 
Dimensions 
299 × 248 × 119 mm 
Weight 
Approx. 4 kg 
IP protection class 
IP40 
Reference temperature range 
20 °C 
 5 °C 
Working temperature range 
0 ... 40 °C 
Storage temperature range 
-10 ... 50 °C 
Reference humidity range 
10 ... 60 % relative humidity w/o condensation 
Working humidity range 
10 ... 85 % relative humidity w/o condensation 
Degree of pollution 
Altitude above sea level 
  2000 m max.