Posital Fraba ACS-080-2-CA01-HE2-PM Inclination Sensor 2 axes Reading range(s) -80/+80 ° ACS-080-2-CA01-HE2-PM Manuel D’Utilisation

Codes de produits
ACS-080-2-CA01-HE2-PM
Page de 44
 
ACS CANopen Manual 
 
 
 
 
 
 
 
 
 
 
 
Version 20110928 
 
 
 
15 of 44 
AC C E L E N S   ( AC S )  C AN o p e n  
4.3. Programmable Parameters 
 
Objects  are  based  on  the  CiA  410  DS  V1.2: 
CANopen  profile  for  inclinometer  (
www.can-
cia.org
).  The  following  table  gives  the  list  of 
command  identifiers  sent  and  received  by  the 
inclinometer.  These  are  the  standard  commands 
used for communication and transmission between 
a  master  and  slave  in  the  CAN  bus.  It  is  quite 
useful  for  the  analysis  of  communication  logs 
between  the  master  and  slave  and  for  better 
understanding of the system under observation. 
 
Command 
Function 
Telegram 
Description 
22h 
Domain Download 
Request 
Parameter to ACS 
60h 
Domain Download 
Confirmation 
Parameter received 
40h 
Domain Upload 
Request 
Parameter request 
43h, 4Bh, 4Fh (*) 
Domain Upload 
Reply 
Parameter to Master 
80 h 
Warning 
Reply 
Transmission error 
Table 1: Command Description 
 (*)The value of the command byte depends on the data length of the called parameter. 
 
Command 
Data length 
Data length 
43h 
4 Byte 
Unsigned 32 
4Bh 
2 Byte 
Unsigned 16 
4Fh 
1 Byte 
Unsigned 8 
Table 2: Data Length of Commands 
 
The  following  list  of  objects  is  the  most  frequently  used  objects  while  programming  the  CANopen  ACS 
inclinometer. The whole list of objects is available in Appendix A. 
 
 
Position Value 
(Objects 6010h, 6020h) 
The  objects  6010h  and  6020h  are  used  to  get  the  inclination  positions 
from ACS080 in the range of ±80° and the object 6010h is used to get the 
inclination position from ACS360 in the range of 0 - 360°. 
Store Parameters 
(Objects 1010h, 2300h)  
These  objects  are  used  to  store  any  re-configured  parameters.  Object 
1010h  just  stores  the  parameters  whereas  2300h  stores  and  saves  the 
parameters upon reset of the ACS.