Posital Fraba ACS-080-2-CA01-HE2-PM Inclination Sensor 2 axes Reading range(s) -80/+80 ° ACS-080-2-CA01-HE2-PM Manuel D’Utilisation

Codes de produits
ACS-080-2-CA01-HE2-PM
Page de 44
 
ACS CANopen Manual 
 
 
 
 
 
 
 
 
 
 
 
Version 20110928 
 
 
 
37 of 44 
AC C E L E N S   ( AC S )  C AN o p e n  
Object 2600h: Preset  X/Z-Axis  
In  ACS080  inclinometers,  this  object  sets  the  X-axis  to  a  desired  value.  In  ACS360  inclinometers,  this 
object sets the Z-axis to a desired value. 
Subindex  
Description  
Data Type  
Default Value   Access  
Restore  after 
BootUp  
0  
-  
Integer 16  
-  
rw  
no  
  
*Currently available only in ACS360 versions. Although it is given both Read and Write access, it is 
preferable to use only write command for setting the Preset value of ACS. Upon setting the Preset 
value a save command has to be given in order to set the Preset value finally. 
 
 
Object 3000h: Node Number 
This object contains the node number of the device. The POSITAL standard node number is 32decimal
 5
Subindex  
Description  
Data Type  
Default Value   Access  
Restore  after 
BootUp  
0  
Node Number  
Unsigned 8  
1Fh  
rw*  
yes  
 
NOTE: To avoid the node number zero (0), one (1) will be added to the value of this object. 
E.g.: 1Fh+1h = 20h = 32 (dec) 
 
*Upon changing the node number please use 2300h object to save the set node number. 
 
 
Object 3001h: Baudrate 
This object contains the baud rate of the device. 
Subindex  
Description  
Data Type  
Default Value   Access  
Restore  after 
BootUp  
0  
Baudrate  
Unsigned 8  
-  
rw*  
yes  
 
Eight different baud rates are provided. To adjust the baud rate only one byte is used. 
The default baud rate is 20 kB
6
Baudrate 
in kB  
Byte  
20  
00h  
50  
01h  
100  
02h  
125  
03h  
250  
04h  
500  
05h  
800  
06h  
1000  
07h  
                                                            
6
 Forthcoming ACS model will have a default baud rate of 125kB.