Cellpack DUCT SEAL 240358 Fiche De Données

Codes de produits
240358
Page de 4
Status: 25.07.2011 
Trade name: Duct Seal 
Product no.: M1 
Version: 1.0.0 / GB 
EC safety data sheet 
 
 
 
 
 
page   2(4) 
5.) 
Fire-fighting measures 
Suitable extinguishing media 
Carbon dioxide; Foam; Dry chemicals; Water spray jet 
Extinguishing media that must not be used for safety reasons 
Full water jet 
Special exposure hazards arising from the substance or preparation itself, combustion products, resulting 
gases 
In the event of fire, the following can be released: Carbon monoxide and carbon dioxide 
Special protective equipment for fire-fighters 
When extinguishing fires, use breathing apparatus with an independent source of air. Wear protective clothing. 
  
6.) 
Accidental release measures 
Personal precautions 
Refer to protective measures listed in sections 7 and 8. 
Environmental precautions 
No special measures necessary. 
Methods for cleaning up/taking up 
Take up mechanically. Clean contaminated surfaces thoroughly. 
  
7.) 
Handling and storage 
Handling 
Advice on safe handling 
No special measures necessary. 
Advice on protection against fire and explosion 
No special measures necessary. 
Storage 
Requirements for storage rooms and vessels 
Store product in closed containers. 
Advice on storage assembly 
Do not store together with acids. 
Further information on storage conditions 
Keep container tightly closed, cool and dry. 
  
8.) 
Exposure controls / personal protection 
Exposure limit values 
N O N E 
 
Exposure controls 
Personal protective equipment 
Respiratory protection 
No special measures required. 
Hand protection 
No special measures required. 
Eye protection 
No special measures required. 
Skin protection 
No special measures required. 
General protective and hygiene measures 
Keep away from foodstuffs and beverages. Do not eat or drink during work - no smoking.