Tele Thyristor control module 1-phase TST1 15 499991 Fiche De Données
Codes de produits
499991
9. Power classes
10. Ambient conditions
Ambient temperature:
0 to +45°C (accordimg to IEC 68-1)
Storage temperature:
-10 to +70°C
Transport temperature:
-10 to +70°C
Relative humidity:
5% to 95% not condensing
(according to IEC 721-3-3 class 3K3)
Pollution degree:
2 (according to IEC 664-1)
Thyristor control units - TST series
TST
Industrial design
Compact construction
1-phase connection
Phase-angle or multi-cycle control
Compact construction
1-phase connection
Phase-angle or multi-cycle control
(depends on selected unit)
6.01-1
1. Device type
The TST can be ordered with two types of power control
TST
Phase-angle control remote controlable
TST-SP
Multi-cycle control remote controlable
2. Indicators
Green LED RUN:
indication of operation
Yellow LED Start:
indication of activation
Yellow LED 100%U
load
: indication of max. output voltage
Red LED Fault:
indication of fault resp.
indication of overtemperature
3. Mechanical design
Aluminium housing, IP rating IP20
Mounted on DIN-Rail TS 35 according to EN 50022
Mounting position:
any
Master control unit:
Terminals:
PCB terminals 2.5mm
2
Initial torque:
max. 0.5Nm
Power section:
Shockproof terminal connection according to VBG 4, IP rating IP 20
Terminal capacity:
1 x 16mm
2
with/without multicore cable end
4. Input circuit
Supply voltage:
230V AC
(other voltages on request, e.g. 110V, 400V,
500V AC or internally generated)
Toleranzce
±15%
Rated frequency:
45 to 65Hz (automatically synchronised)
Duration of operation: 100%
5. Control contact 1-2
Function:
activation
Connections:
potential free, terminals 1-2
Loadable:
No
Line length:
max. 10m, twisted pair
6. Control contact 3-4-5
Function:
setting of firing angle
Input impedance:
500Ω/50kΩ (switchable)
Activation:
Potentiometer 2.5 to 47kΩ
or control signal 0 to 10V resp.
0 to 20mA (switchable)
Line length:
max. 10m, twisted pair
7. Signaling contact 6-7
1 potential free normally open contact
Function:
indication of fault
Switching capacity:
2A / 230V AC1
8. Power circuit
Load voltage:
1~ 110V to 500V AC
terminals L1-L2, T1-T2
Tolerance:
±15%
Technical data
Subject to alterations and errors
Release 11/01
Type
TST 15
TST 25
TST 35
TST 50
max. load current
15A
25A
35A
50A