Panasonic ST124F PCB Mount Relay 24V 1 NO / 1 NC ST124F Fiche De Données

Codes de produits
ST124F
Page de 5
ST
5
ds_61A09_en_st: 070313D
PRECAUTIONS FOR USE (SOCKET)
ACCESSORIES
ST RELAYS 
SOCKET
VDE
ST relay socket
ST-PS
PC board terminal socket
ST-SS
Solder terminal socket
FEATURES
1. Possible to fit or remove the 
chassis with one touch (t = 0.6 mm 
to 2.2 mm 
.024 inch to .087 inch
)
2. Easy design of PC board pattern
(2.54 mm x 4 pitch DIL terminal array)
3. Complies with Japan Electrical 
Appliance and Material Safety Law.
(UL and VDE certification)
4. High breakdown voltage.
SPECIFICATIONS
Item
Specifications
Breakdown voltage (Initial)
Between contact and coil: 4,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and terminal: 2,000 Vrms for 1 min.
Insulation resistance (Initial)
Min. 1,000 M
 between terminals (500V DC)
Heat resistance
150
C 
302
F
 for 1 hr
Max. continuous current
10 A
Relay insertion life
15 times
31.6
35.4
16.6
8
1
7
2
6
3
5
4
14.6
16.4
10.16
1.05
0.3
5.5
4
4.3
0.27
10.16
7.62
7.62
1.244
1.394
.654
.575
.646
.400
.041
.012
.217
.158
.169
.011
.400
.300
.300
31.6
35.4
16.6
8
1
7
2
6
3
5
4
14.6
16.4
10.16
2.3
0.3
5.5
4
5.3
0.27
10.16
7.62
7.62
1.244
1.394
.654
.575
.646
.400
.012
.217
.158
.209
.011
.400
.300
.300
.090
DIMENSIONS 
(Unit: mm 
inch
)
ST-PS
ST-SS
1. PC board mounting method
PC board pattern
The terminal configuration is symmetrical 
on the left and right, so an arrow mark 
 
is stamped on the socket to prevent mis-
insertion. We recommend printing the 
same arrow mark 
 on the component 
mounting side (side opposite from 
pattern) of the PC board. In this case, the 
terminal configuration becomes the 
terminal nos. noted near the drilling 
holes.
2. Chassis cutout
Chassis cutting dimensions
If the chassis hole is punched with a 
press, set so the release R on the front 
side (A side).
The range for chassis thickness is 0.6 to 
2.2 mm 
.024 to .087 inch
.
3. Relay mounting and removal
(1) Align the directions of the relay and 
socket.      
(2) Insert the relay all the way in, so it is 
securely in place.
(3) Press the part indicated by A in the B 
direction, and fasten by placing the hook 
on the relay.
(4) When removing the relay, completely 
release the hooks on both sides and pull 
the relay out.
2.54
8-1.5 dia.
8
7
6
5
1
2
3
4
2.54
Contact
terminal
interval
Coil
terminal
interval
.100
8-.060 dia.
.100
15.0
±0.2
32.5
±0.1
.591
±.008
1.280
±.004
Claw for chassis
fastening
Chassis t = 0.6 to 2.2
Press
A side
.024 to .087
Relay
Hinge
mechanism
Relay case
cross-section
B
(Fastening complete)
(Before fastening)
A