Connections
3-wire-circuit
 
C1  C2
 
 
 
 
B1  N
 
 
L
 
N
 
8-230V 
AC/DC 
+  - 
18
18
L
B1
N
4-wire-circuit with attic illumination
 
C1  C2 
B1  N 
L
 
N
 
8-230V 
AC/DC 
+  - 
18
 
 
 
 
18
L
B1
N
Dimensions
 
 
 
 
 
 
 
 
 
17,5mm 
44mm 
60mm 
87
m
m
 
45
m
m
 
5mm 
Functions
Function automatic timer (T, TW): After the pushbutton at B1 has been 
pressed, the output relay R closes (terminals L-18) and the set interval 
t begins. If the pushbutton is pressed again  before the interval t has 
expired, the interval begins again (restart function complies with EN 
60669-2-3). Rapid, multiple pressing of the pushbutton (pumping) adds 
2, 3 or more time intervals to extend the time up to 60min. Prolonged 
pressure on the button (>2s) aborts the interval running and switches the 
relay off (energy saving function). In the TW mode the device provides 
a switch-off warning (in accordance with DIN 180-158-2) by generating 
short pulses (flashing) at 30s, 15s and 5s prior to switch-off. 
 
B1 
 
 
2t 
3t 
<2s 
>2s 
<2s 
>2s 
 
 
 
 
 
15s
10s 5s
TW
T
 
Operating possibilities at B1 in mode T and TW:
Switch ON
Retrigger
Time extension function (pumping)
Switch OFF
The additional control input C1-C2 can be used in the T and TW modes to 
control the staircase lighting timer with a voltage of 8 to 230V AC/DC. This 
input can be used to start and restart the cycle. It cannot be used for switch-
off (energy saving function) or for programming long intervals (pumping).
Impulse switch mode (P), (PN): n this mode, every keypress toggles 
the output relay R (flip-flop). In function P, the output relay R remains in 
off-position, whenever the supply voltage is applied. In function PN, the 
output relay R switches into on-position after applying the supply voltage 
U, if the output relay R was in on-position last before power failure. The 
output relay R switches into on-position, if a short voltage impulse (<2s) 
is applied to the additional control input (C1-C2). (central ON) A longer 
voltage impulse (>2s) opens the output relay R. (central OFF)
 
C1-C2 
B1 
 
 
P
<2s 
>2s 
>2s  >2s 
<2s 
 
C1-C2 
B1 
 
 
PN 
<2s 
>2s 
>2s  >2s 
<2s 
Mode
Mode
RELEASE 2009/07
Subject to alterations and errors
Ordering Informations
Types
Functiones
Supply Voltage
Part. No.
E1ZTP 230V AC
TW, 1, 0, P
230V AC
110301
E1ZTPNC 230V AC
T, TW, 1, 0, P, PN
230V AC
110300