MEAN WELL LED driverLED-switching power supply LCM-40 LCM-40 Fiche De Données

Codes de produits
LCM-40
Page de 5
SPECIFICATION
MODEL
LCM-40
DC VOLTAGE RANGE
RATED POWER
OUTPUT
SETUP, RISE TIME
Note.5
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
TOTAL HARMONIC DISTORTION
EFFICIENCY (Typ.)
Note.6
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
2 ~ 100V
2 ~ 67V
2 ~ 80V
2 ~ 57V
2 ~ 45V
2 ~ 40V
42W
700mVp-p
110V
65V
500ms, 80ms / 230VAC at
rated power
180 ~ 295VAC          254 ~ 417VDC
47 ~ 63Hz
Total harmonic distortion will be lower than 20% when output loading is 75% or higher
91%
COLD START 20A(t
=260 s measured at 50% I
) at 230VAC
width
peak
μ
<0.5mA / 240VAC
Compliance to EN55015, EN61000-3-2 Class C( 40%
) ; EN61000-3-3; GB17625.1,GB17743
rated power
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547 light industry level (surge 2KV),  criteria A
-30 ~ +60
(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for  60min. each along X, Y, Z axes
260.6K hrs min.      MIL-HDBK-217F (25
)
123.5*81.5*23mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25  of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf parallel capacitor.
3. Please see "DIP switch table".
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Efficiency is measured at 500mA/80V output set by DIP switch.
7. No load power consumption<1W is measured at 180 277VAC, with lighting fixture connected and output current dimmed to 0%.
~
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the 
    complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently 
    connected to the mains.
0.24Kg ; 54pcs/15Kg/1.12CUFT
40W Multiple-Stage Output Current LED Power Supply
L C M - 4 0
s e r i e s
RIPPLE & NOISE (max.)
Note.2
NO LOAD OUTPUT VOLTAGE (max.)
ENVIRONMENT
SAFETY &
FUNCTION
EMC
PROTECTION
16ms/230VAC at
rated power
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
UL8750, ENEC EN61347-1, EN61347-2-13, EN62384 independent,GB19510.14,GB19510.1 approved
I/P-O/P:>100M Ohms / 500VDC / 25
/ 70% RH
File Name:LCM-40-SPEC 2014-10-27
SELECTABLE CURRENT
Note.3
350mA
600mA
500mA
700mA
900mA
1050mA
±5.0%
CURRENT ACCURACY
EMC IMMUNITY
EMC EMISSION
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
AUXILIARY POWER
TEMP. COMPENSATION
SYNCHRONIZATION
Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shutdown o/p voltage, re-power on to recover
110 ~ 130V
Shut down o/p voltage, re-power on to recover
12V @ 50mA for driving fan; Tolerance 5%
±
By external NTC(not provide with the power supply), please see "Temperature Compensation Operation"
Please see "Synchronization Operation"
DIMMING
Please see "Dimming Operation"
0.23A/230VAC          0.2A/277VAC
RIPPLE CURRENT
 Features :

Output current level selectable by DIP S.W.

180~295VAC input only

Built-in active PFC function

Protections: Short circuit / Over voltage / Over temperature

Cooling by free air convection

Fully isolated plastic case

Class   power unit, no FG

Built-in 0~10Vdc and PWM signal dimming function

Built-in 12V/50mA auxiliary output

IP20 design

Temperature compensation function by external NTC

No load power consumption <1W(Note.7)

Power supplies synchronization function up to 10 units

Suitable for indoor LED lighting applications

3 years warranty
PF 0.975/230VAC, PF 0.96/277VAC at
(Please refer to "Power Factor Characteristic" curve)
rated power
±5.0%
SELV
F
M
M
110