SPECIFICATION
MODEL
PLC-60-12
PLC-60-15
PLC-60-20
PLC-60-24
PLC-60-27
PLC-60-36
PLC-60-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE          
RATED POWER               
OUTPUT
LINE REGULATION      
LOAD REGULATION      
 
SETUP TIME
VOLTAGE RANGE          
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (max.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER CURRENT   
SHORT CIRCUIT            
OVER VOLTAGE           
 
OVER TEMPERATURE
12V
15V
20V
24V
27V
36V
48V
5A
4A
3A
2.5A
2.3A
1.7A
1.3A
0 ~ 5A
0 ~ 4A
0 ~ 3A
0 ~ 2.5A
0 ~ 2.3A
0 ~ 1.7A
0 ~ 1.3A
60W
60W
60W
60W
62.1W
61.2W
62.4W
2Vp-p
2.4Vp-p
1.8Vp-p
2.4Vp-p
2.7Vp-p
3.6Vp-p
4.6Vp-p
±10%
±3.0%
±5.0%
1500ms / 230VAC    3000ms / 115VAC at full load
90 ~ 264VAC          127 ~ 370VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.9/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
85%
86%
87.5%
87%
88%
89%
89%
13.8 ~ 16V
17.5 ~ 21V
23 ~ 26V
28 ~ 32V
31 ~ 35V
41 ~ 46V
54 ~ 60V
0.8A/115VAC     0.4A/230VAC
<0.75mA / 240VAC
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
-30 ~ +50
 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±
0.03%/
 (0 ~ 50
)
10 ~ 500Hz, 2G 12min./1cycle, period for  72min. each along X, Y, Z axes
UL1310, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), J61347-1, J61347-2-13 approved
515K hrs min.      MIL-HDBK-217F (25
)
181.5*62*35mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25  of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.   
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
6.  lease refer to "DRIVING METHODS OF LED MODULE".
P
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the 
    complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
0.41Kg; 30pcs/13.3Kg/0.67CUFT
60W Single Output LED Power Supply
Universal AC input / Full range
High efficiency up to 89%
Adjustable output voltage and current level
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Built-in constant current limiting circuit
Fully isolated plastic case with terminal block style of I/O
Built-in active PFC function, comply with EN61000-3-2 class C
     (
75% load)
Class 2 power unit
ass LPS
P
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications 
(Note.2)
Compliance to worldwide safety regulations for lighting 
2 years warranty
 Features :
P L C - 6 0  
s e r i e s
RIPPLE & NOISE (max.)  
Note.2
VOLTAGE TOLERANCE  
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, recovers automatically after temperature goes down
File Name:PLC-60-SPEC   2014-03-13
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC     I/P-FG:2KVAC     O/P-FG:0.5KVAC
I/P-O/P:100M Ohms / 500VDC / 25
/ 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (
75% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level,  criteria A
95 ~ 110%
Protection type : Shut down o/p voltage, re-power on to recover
10.5 ~15V
14 ~ 20V
16.8 ~24V
18.9 ~27V
25.2 ~ 36V
33.6 ~ 48V
8.4 ~ 12V
CONSTANT CURRENT REGION 
Note.6
VOLTAGE ADJ. RANGE 
Note.5
CURRENT ADJ. RANGE 
Note.5
11.5 ~ 13V
3.75 ~ 5.15A
14.5 ~ 16.2V
3 ~ 4.12A
19.5 ~ 22V
2.25 ~ 3.09A
24 ~ 26V
1.875 ~ 2.575A
25 ~ 30V
1.725 ~ 2.369A
32.5 ~ 39V
1.275 ~ 1.751A
43.6 ~ 51.8V
0.975 ~ 1.339A
EMC IMMUNITY
EMC EMISSION
( for 48V only)
( except for 48V )
F
M
M
110
LPS
SELV
COLD START 35A(t
=35  s measured at 50% I
) at 230VAC 
width
peak
μ