MEAN WELL LED driverLED-switching power supply PLN-30-12 PLN-30-12 Fiche De Données

Codes de produits
PLN-30-12
Page de 3
SPECIFICATION
MODEL
PLN-30-9
PLN-30-15
PLN-30-12
PLN-30-20
PLN-30-24
PLN-30-27
PLN-30-36
PLN-30-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
Note.5
CURRENT ADJ. RANGE
Note.5
LINE REGULATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
9V
15V
10.5 ~ 15V
12V
8.4 ~ 12V
20V
14 ~ 20V
24V
16.8 ~ 24V
27V
18.9 ~ 27V
36V
25.2 ~ 36V
48V
33.6 ~ 48V
3.3A
2A
2.5A
1.5A
1.25A
1.12A
0.84A
0.63A
0 ~ 3.3A
0 ~ 2A
0 ~ 2.5A
0 ~ 1.5A
0 ~ 1.25A
0 ~ 1.12A
0 ~ 0.84A
0 ~ 0.63A
29.7W
30W
30W
30W
30W
30.24W
30.24W
30.24W
2.6Vp-p
2.6Vp-p
2Vp-p
2.6Vp-p
2.6Vp-p
2.3Vp-p
4.5Vp-p
3.7Vp-p
-5% ~ 10%. Can be adjusted by internal potentiometer SVR1
3% ~  -25%. Can be adjusted by internal potentiometer SVR2
±3.0%
±10%
±5.0%
500ms / 230VAC    3000ms / 115VAC at full load
90 ~ 295VAC          127 ~ 417VDC
47 ~ 63Hz
PF>0.95/115VAC, PF>0.9/230VAC, PF>0.9/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
80%
83.5%
82.5%
84%
84%
84.5%
85%
85.5%
10 ~ 14V
17 ~ 22V
14 ~ 17V
23 ~ 26V
27 ~ 34V
31 ~ 35V
40 ~ 50V
53 ~ 63V
COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VAC
μ
<0.5mA / 240VAC
100 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25
/ 70% RH
-30 ~ +50
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
, 10 ~ 95% RH
±
0.06%/
(0 ~ 50
)
10 ~ 500Hz, 2G 12min./1cycle, period for  72min. each along X, Y, Z axes
621.4Khrs min.      MIL-HDBK-217F (25
)
145*47*30mm (L*W*H)
File Name:PLN-30-SPEC   2014-08-14
0.22Kg; 60pcs/14.2Kg/1.25CUFT
Protection type : Shut down o/p voltage, re-power on to recover
30W Single Output LED Power Supply

Universal AC input / Full range (up to 295VAC)

Protections: Short circuit / Over current / Over voltage / Over temperature 

Cooling by free air convection

Built-in constant current limiting circuit with adjustable OCP level

Fully isolated plastic case with IP64 level

Built-in active PFC function

Pass LPS

Class   power unit, no FG

Class 2 power unit

100% full load burn-in test

High reliability

Suitable for LED lighting and moving sign applications 
(Note.2)

Compliance to worldwide safety regulations for lighting 

2 years warranty
 Features :
P L N - 3 0
s e r i e s
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
IP64
..
( except for 48V )
F
M
M
110
LPS
SELV
6.3 ~ 9V
CONSTANT CURRENT REGION
Note.6
Compliance to EN55015, EN61000-3-2 Class C (pin 25W), Class D (>70% load) ; EN61000-3-3
( for 48V only)
( except for 48V )
EMC IMMUNITY
EMC EMISSION
0.4A/115VAC           0.2A/230VAC           0.15A/277VAC
UL879, UL1310, CSA C22.2 No. 207-M89(except for 48V), TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No.223-M91
(except for 48V),IP64, J61347-1,J61347-2-13 approved
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level,  criteria B
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25  of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.
6.  lease refer to "DRIVING METHODS OF LED MODULE".
P
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the 
    complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently 
      connected to the mains.