Panasonic DSP1-5V-F PCB Mount Relay DSP15FD Fiche De Données

Codes de produits
DSP15FD
Page de 7
DSP
7
ds_61A05_en_dsp: 070313D
DIMENSIONS 
(Unit: mm 
inch
)
FIXING AND REMOVAL METHOD
ACCESSORIES
SOCKETS FOR 
DS-P RELAYS
TYPES AND APPLICABLE RELAYS
SPECIFICATIONS
Type No.
Applicable relays
For DSP1a
For DSP1a, DSP1, DSP2a
DSP1a-PS
DSP1a-PSL2
DSP2a-PS
DSP2a-PSL2
DSP1a relays
OK
OK
OK
OK
DSP1a-L2 relays
OK
OK
DSP1 relays
OK
OK
DSP1-L2 relays
OK
DSP2a relays
OK
OK
DSP2a-L2 relays
OK
Item
Specifications
Breakdown voltage
3,000 Vrms between terminals
(Except for the portion between coil terminals)
Insulation resistance
1,000 M
 between terminals at 500 V
Heat resistance
150
C for 1 hour
Max. continuous current
8 A
External dimensions
PC board pattern (Bottom view)
 5.7
±0.3
 17
±0.6
 11
±0.6
 23
±0.6
0.3
±0.1
 7.62
±0.3  10.16±0.3
0.8
±0.1
0.65
±0.1
7.62
±0.3
2.54
±0.3
3.7
2.61
.224
±.012
.669
±.024
.433
±.024
.906
±.024
.012
±.004
.300
±.012 .400±.012
.031
±.004
.026
±.004
.300
±.012
.100
±.012
.146
.103
DSP1a-PS, DSP1a-PSL2
Terminal No.2 and 15 are for 
DSP1a-PSL2 only.
DSP2a-PS, DSP2a-PSL2
Terminal No.2 and 15 are for 
DSP2a-PSL2 only.
1
2
15
16
5
8
2.54
2.54
1.2 dia.
047 dia.
.100
.100
1
2
15
16
5
8
12
9
2.54
2.54
1.2 dia.
047 dia.
.100
.100
1. Match the direction of relay and 
socket.
2. Both ends of relays are fixed so tightly 
that the socket hooks on the top surface 
of relays.
3. Remove the relay, applying force in the 
direction shown below.
4. In case there is not enough space for 
finger to pick relay up, use screw drivers 
in the way shown below.
Notes: 1. Exercise care when removing relays. If 
greater than necessary force is applied at 
the socket hooks, deformation may alter the 
dimensions so that the hook will no longer 
catch, and other damage may also occur.
2. It is hazardous to use IC chip sockets.
Good