Crydom D53TP50D 3 Phase Conductor Relay D53TP50D Fiche De Données

Codes de produits
D53TP50D
Page de 6
INPUT SPECIFICATIONS (1)
Description
D53
A53
Control Voltage Range 
4-32 VDC
90-280 Vrms
Minimum Turn-On Voltage 
4.0 VDC
90 Vrms
Minimum Turn-Off Voltage
1.0 VDC
10 Vrms
Minimum Input Current (for on-state)
19 mA @ 4V
2.2 mA @ 120V
Maximum Input Current 
25 mA @ 32V
10mA @ 240V
Nominal Input Impedance 
Current Limiter
Current Limiter
Maximum Turn-On Time  [msec] (5)
1/2 Cycle
50
Maximum Turn-Off Time  [msec] 
1/2 Cycle
50
GENERAL SPECIFICATIONS
Description
Parameters
Dielectric Strength, Input/Output/Base (50/60Hz)
4000 Vrms
Minimum Insulation Resistance (@ 500 V DC)
10
9
 Ohm
Maximum Capacitance, Input/Output
8 pF
Ambient Operating Temperature Range
-40 to 80°C
Ambient Storage Temperature Range
-40 to 125 °C
Weight (typical)
10.3 oz (315g)
Encapsulation
Thermally conductive Epoxy
Terminals
Nickel plated Brass
Screws and Saddle clamps
Zinc plated Steel
Input Terminal Screw Torque Range:[in lbs/Nm]
8-10 / 0.9-1.1
Output Terminal Screw Torque Range:[in lbs/Nm]
15-20 / 1.7-2.2
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified. 
2) Relay will self trigger between 900-1200 Vpk. 
3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 
4) Heat sinking required, see page 4 for derating curves. 
5) Turn-on time for  Random turn-on versions is 0.02 msec (DC Control Models)