All the receivers in room A have also been programmed to a local master address. For the local
master address 44 is always set as the subaddress, while one of the 15 local master addresses
is selected via the address group. The range available for the address group is once again
between 11 and 43 (11, 12, 13, 14, 21, 22, 23, 24, 31, 32, 33, 34, 41, 42, 43).
In addition, all the lamps in the house can be controlled via the global master address 4444.
The awning was not programmed to this address and can therefore only be controlled via its
single address.
The ceiling lamps in all the rooms are also combined in a function group and can therefore be
jointly controlled.
To select one of the 15 function groups, you need to set 44 as the address group and a value
between 11 and 43 (11, 12, 13, 14, 21, 22, 23, 24, 31, 32, 33, 34, 41, 42, 43) as the subaddress.